Dell PowerEdge M620 Owners Manual - Page 83
number, all PCI devices. If system completes POST, update system BIOS.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Error Code CPU0002 CPU0003 CPU0004 CPU0005 CPU0006 Message Information LCD Message Details Action CPU has a thermal trip. Check CPU heat sink. The processor temperature increased beyond the operational range. Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet temperature (if available) and reinstall processor heat-sink. Message Action CPU has failed the built-in self-test (BIST). 1. Turn system off and remove input power for one minute. Reapply input power and turn system on. 2. Make sure the processor is seated correctly. 3. If the issue persists, see Getting Help. Message Action CPU is stuck in POST. 1. Turn system off and remove input power for one minute. Reapply input power and turn system on. 2. Reduce system configuration to minimum memory and remove all PCI devices. If system completes POST, update system BIOS. reinstall memory and PCI one component at a time to meet the original configuration. 3. If the issue persists, see Getting Help. Message Action CPU failed to initialize. 1. Turn system off and remove input power for one minute. Reapply input power and turn system on. 2. Make sure the processor is seated correctly. 3. If the issue persists, see Getting Help. Message LCD Message Details Action Message Details CPU configuration is unsupported. CPU configuration is unsupported. Check CPU or BIOS revision. System is unable to boot or may run in a degraded state. Review the technical specifcations for supported processor types. Unrecoverable CPU complex error detected on CPU . System is unable to boot or may run in a degraded state. 83