Dell PowerEdge M620 Owners Manual - Page 107

memory for system operation., System BIOS detected memory, but was unable to con

Page 107 highlights

Error Code PDR1024 PST0128 PST0129 PST0130 PST0131 Message Information Details Action The controller detected that the drive was removed. Verify drive installation. Re-seat the failed drive. If the issue persists, see Getting Help. Message LCD Message Details Action Drive mismatch detected for drive in disk drive bay . Drive mismatch detected for drive in bay . Install correct drive type. The installed disk does not meet the array requirements, for example a SATA disk may not operate in an array containing SAS drives. Verify that the disk meets the array requirements. Message LCD Message Details Action No memory is detected. No memory is detected. Inspect memory devices. System BIOS was unable to detect memory in the system . Re-seat the memory modules. If the issue persists, see Getting Help. Message LCD Message Details Action Memory is detected, but is not configurable. Memory is detected, but is not configurable. Check memory devices. System BIOS detected memory, but was unable to configure the memory for system operation. Compare system memory installation to supported system memory configurations. Message LCD Message Details Action Memory is configured, but not usable. Memory is configured, but not usable. Check memory devices The system BIOS encountered device failures or speed configurations that resulted in unused memory. Re-seat the memory modules. If the issue persists, see Getting Help. Message LCD Message Details Action System BIOS shadow failed. System BIOS shadow failed. Check memory devices. Memory errors occurred copying BIOS image into system memory. Remove input power. Reduce system memory to minimum configuration and apply input power. 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

Error Code
Message Information
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue persists,
see
Getting Help
.
PDR1024
Message
Drive mismatch detected for drive <
number
> in disk drive bay <
bay
>.
LCD Message
Drive mismatch detected for drive <
number
> in bay <
bay
>. Install
correct drive type.
Details
The installed disk does not meet the array requirements, for example
a SATA disk may not operate in an array containing SAS drives.
Action
Verify that the disk meets the array requirements.
PST0128
Message
No memory is detected.
LCD Message
No memory is detected. Inspect memory devices.
Details
System BIOS was unable to detect memory in the system .
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
PST0129
Message
Memory is detected, but is not configurable.
LCD Message
Memory is detected, but is not configurable. Check memory devices.
Details
System BIOS detected memory, but was unable to configure the
memory for system operation.
Action
Compare system memory installation to supported system memory
configurations.
PST0130
Message
Memory is configured, but not usable.
LCD Message
Memory is configured, but not usable. Check memory devices
Details
The system BIOS encountered device failures or speed
configurations that resulted in unused memory.
Action
Re-seat the memory modules. If the issue persists, see
Getting Help
.
PST0131
Message
System BIOS shadow failed.
LCD Message
System BIOS shadow failed. Check memory devices.
Details
Memory errors occurred copying BIOS image into system memory.
Action
Remove input power. Reduce system memory to minimum
configuration and apply input power.
107