Dell PowerEdge M620 Owners Manual - Page 130
The control panel temperature is outside of the allowable range.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Error Code TMP0130 TMP0132 TMP0134 VLT0100 VLT0101 Message Information Message LCD Message Details Action The control panel temperature is less than the lower warning threshold. Control panel temperature is outside of range. Ambient air temperature is too cool. Check the system operating environment. Message LCD Message Details Action The control panel temperature is greater than the upper warning threshold. Control panel temperature is outside of range. Ambient air temperature is too warm or one or more fans may have failed. Check the system operating environment and review event log for fan failures. Message LCD Message Details Action The control panel temperature is outside of the allowable range. Control panel temperature is outside of range. Ambient air temperature is too warm or cool. Check the system operating environment and review event log for fan failures. Message LCD Message Details Action Processor module voltage is less than the lower warning threshold. Processor module voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Processor module voltage is less than the lower critical threshold. Processor module voltage is outside of range. 130