Dell PowerEdge MX7000 EMC OpenManage Enterprise-Modular Edition Version 1.10.2 - Page 16
Build Time: 2020-02-15T00:45:32+0000, System Type: MX9116N-ON
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Build Version: 10.5.0.5.661 Build Time: 2020-02-15T00:45:32+0000 System Type: MX9116N-ON Architecture: x86_64 Up Time: 1 day 20:37:53 MX9116N-A2# 5. Run the command, show smartfabric cluster member, in the Master networking switch. Confirm that the STATUS of the upgraded switch is ONLINE in the command output, after it has reloaded. IOM# show smartfabric cluster member Service-tag IP Address Status Role Type Chassis-Slot MXWV122 xxxxxxxxxxx ONLINE MASTER MX9116n SKYMX02 MXLE103 xxxxxxxxxxx ONLINE BACKUP MX9116n SKYMX10 MXLE093 xxxxxxxxxxx ONLINE BACKUP MX9116n SKYMX09 MXWV011 xxxxxxxxxxx ONLINE BACKUP MX9116n SKYMX01 Chassis-Service-Tag A2 B2 B1 A1 6. After step 5 is completed, proceed with upgrading the next Networking I/O Module. 16 Updating the management module firmware