Dell PowerEdge MX7000 EMC OpenManage Enterprise-Modular Edition Version 1.10.2 - Page 81
VLAN scaling guidelines
View all Dell PowerEdge MX7000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
• Other 6. Define the tagged and untagged VLANs to modify the VLAN selections as required. 7. Select VLANs on Tagged and Untagged Network for each Mezzanine card port. 8. Click Save. VLAN scaling guidelines The number of recommended VLANs differs between the modes as SmartFabric mode provides network automation capabilities that Full Switch mode does not. The following table lists the maximum number of VLANs recommended per fabric, Uplink, and server port: Table 21. Maximum number of VLANs recommended in SmartFabric mode OS10 Version Parameter 10.5.0 Maximum VLANs per fabric Maximum VLANs per uplink Maximum VLANs per server port 10.4.0.R3S Maximum VLANs per fabric 10.4.0.R4S Maximum VLANs per uplink Maximum VLANs per server port Value 256 256 64 128 128 32 SmartFabric Services 81