Dell PowerEdge MX7000 EMC OpenManage Enterprise-Modular Edition Version 1.10.2 - Page 25

Chassis Direct, Enable Quick Sync Wi-Fi

Page 25 highlights

NOTE: The Quick Sync feature uses a lower radio frequency (RF) power when advertising and increases the RF power after the certificate authentication. The RF range is based on the environment and can vary. 4. Select Enable Inactivity Timeout to enable the idle timeout and enter the Timeout Limit. Timeout is the idle time when there is no Wi-Fi traffic. Specify inactivity timeout limit, in seconds. The timeout can be between two minutes and 60 minutes. NOTE: The Timeout Limit option is available only if the Enable Inactivity Timeout is selected. 5. Select Enable Read Authentication to use your user credentials to read the inventory in a secure data center. By default, this option is selected. If you clear this check box, you cannot access the secure data center. 6. Select Enable Quick Sync Wi-Fi to use WiFi to communicate with the chassis. By default, the Enable Quick Sync Wi-Fi check box is selected. 7. Select Enable KVM Access to configure the quick sync setting using KVM. You can also use the RACADM or Redfish command to enable or disable KVM. For more information, see the OME - Modular for PowerEdge MX7000 Chassis RACADM CLI Guide available at www.dell.com/openmanagemanuals. You can use the DisplayPort in the chassis to stream the video in the KVM. If the external DP to Video Graphics Array (VGA) converter is available, you can stream the KVM video in the VGA too. 8. Select the LCD Access option for quick sync. The available options are: • Disabled • View Only • View and Modify NOTE: The LCD Access option is displayed only if there is a system with LCD available in the chassis. 9. In the User Defined text box, enter the text that you want to see on the LCD Home screen. The LCD Home screen is displayed when the system is reset to factory default settings. The text can have a maximum of 62 characters and supports a limited number of UTF-8 characters. If a UTF-8 character that is used in the text is not supported, a box is displayed instead of the character. The default string is the service tag of the system. 10. From the LCD Language drop-down, select the language in which the text on the LCD must be displayed. The available options are: • English • French • Spanish • German • Japanese • Chinese By default, the text is displayed in English. 11. Select the Enable Chassis Direct Access text box to enable accessing the MX7000 chassis from a host such as a laptop or server, using a USB On-The-Go (OTG) cable. If the Enable Chassis Direct Access check box is cleared, the existing chassis direct sessions are disconnected and the Chassis Direct LED turns off. When the feature is disabled, you cannot connect the laptop to the chassis. The URL https://ome-m.local is inaccessible. After enabling the feature, reattach the USB cable and wait for Chassis Direct LED to turn green to access the chassis phonebook. For more information, see the section, Chassis Direct. 12. Click Apply to save the quick sync settings. Chassis Direct The Chassis Direct feature in OME-Modular enables users to access management consoles such as iDRAC and management module of devices on the chassis. The MX7000 chassis has several USB ports. The Right Control Panel (RCP) on the front of the chassis has three USB ports. Two ports are regular sized USB-A ports, for keyboards and mouse used for the chassis level KVM. The third port is a MicroAB port that supports USB OTG. To use Chassis Direct, connect the USB OTG port to a laptop. The Poleg processor on the management module emulates a USB network interface and provides a network bridge into the management VLAN. The network is same that QuickSync 2 bridges for OpenManage Mobile WiFi access. Remove the USB cable that is connected to the front panel and AC power cycle the chassis. With the laptop that is connected to the USB OTG port on the chassis, you can access the MM user interface and iDRAC user interface or KVM. You can get access by launching a browser on the laptop and entering the URL, https://ome-m.local. A chassis Logging in to OME-Modular 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

NOTE:
The Quick Sync feature uses a lower radio frequency (RF) power when advertising and increases the RF
power after the certificate authentication. The RF range is based on the environment and can vary.
4.
Select
Enable Inactivity Timeout
to enable the idle timeout and enter the
Timeout Limit
.
Timeout is the idle time when there is no Wi-Fi traffic. Specify inactivity timeout limit, in seconds. The timeout can be between two
minutes and 60 minutes.
NOTE:
The Timeout Limit option is available only if the Enable Inactivity Timeout is selected.
5.
Select
Enable Read Authentication
to use your user credentials to read the inventory in a secure data center.
By default, this option is selected. If you clear this check box, you cannot access the secure data center.
6.
Select
Enable Quick Sync Wi-Fi
to use WiFi to communicate with the chassis. By default, the
Enable Quick Sync Wi-Fi
check box
is selected.
7.
Select
Enable KVM Access
to configure the quick sync setting using KVM. You can also use the RACADM or Redfish command to
enable or disable KVM. For more information, see the
OME - Modular for PowerEdge MX7000 Chassis RACADM CLI Guide
available
at
www.dell.com/openmanagemanuals
.
You can use the DisplayPort in the chassis to stream the video in the KVM. If the external DP to Video Graphics Array (VGA)
converter is available, you can stream the KVM video in the VGA too.
8.
Select the
LCD Access
option for quick sync.
The available options are:
Disabled
View Only
View and Modify
NOTE:
The LCD Access option is displayed only if there is a system with LCD available in the chassis.
9.
In the
User Defined
text box, enter the text that you want to see on the LCD Home screen. The LCD Home screen is displayed when
the system is reset to factory default settings. The text can have a maximum of 62 characters and supports a limited number of
UTF-8 characters. If a UTF-8 character that is used in the text is not supported, a box is displayed instead of the character. The
default string is the service tag of the system.
10.
From the
LCD Language
drop-down, select the language in which the text on the LCD must be displayed.
The available options are:
English
French
Spanish
German
Japanese
Chinese
By default, the text is displayed in English.
11.
Select the
Enable Chassis Direct Access
text box to enable accessing the MX7000 chassis from a host such as a laptop or server,
using a USB On-The-Go (OTG) cable.
If the
Enable Chassis Direct Access
check box is cleared, the existing chassis direct sessions are disconnected and the Chassis
Direct LED turns off. When the feature is disabled, you cannot connect the laptop to the chassis. The URL
https://ome-m.local
is inaccessible. After enabling the feature, reattach the USB cable and wait for Chassis Direct LED to turn green to access the chassis
phonebook. For more information, see the section,
Chassis Direct
.
12.
Click
Apply
to save the quick sync settings.
Chassis Direct
The Chassis Direct feature in OME-Modular enables users to access management consoles such as iDRAC and management module of
devices on the chassis. The MX7000 chassis has several USB ports. The Right Control Panel (RCP) on the front of the chassis has three
USB ports. Two ports are regular sized USB-A ports, for keyboards and mouse used for the chassis level KVM. The third port is a Micro-
AB port that supports USB OTG. To use Chassis Direct, connect the USB OTG port to a laptop. The Poleg processor on the management
module emulates a USB network interface and provides a network bridge into the management VLAN. The network is same that
QuickSync 2 bridges for OpenManage Mobile WiFi access.
Remove the USB cable that is connected to the front panel and AC power cycle the chassis.
With the laptop that is connected to the USB OTG port on the chassis, you can access the MM user interface and iDRAC user interface
or KVM. You can get access by launching a browser on the laptop and entering the URL,
https://ome-m.local
. A chassis
Logging in to OME-Modular
25