Dell PowerVault TL4000 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS - User's G
Dell PowerVault TL4000 Manual
View all Dell PowerVault TL4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerVault TL4000 manual content summary:
- Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 1
DellTM Model TL24iSCSIxSAS 1Gb iSCSI to SASTM Model TL24iSCSIxSAS 1GBb iSCSI to SAS www.dell.com| support.dell.com - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS - User's G - Page 2
- Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 3
in this document to refer to either the entities claiming the marks and names or their products. Dell inc. disclaims any proprietary interest in trademarks and trade names other than its own. For latest revision of this guide, please go to www.support.dell.com. Model TL24iSCSIxSAS 1Gb iSCSI to SAS - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 4
per Port. You will require a SAS cable that supports this connector at the bridge end and the type of connect your peripheral device supports at the other. If you are in any doubt, please contact your reseller for assistance. Page 2 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 5
...8 6. Installing the iSCSI Setting the Password ...25 7.5 Network Services ...26 Defaults ...35 9.4 Firmware Updates ...36 10. Troubleshooting ...38 10.1 Network Problems ...38 10.2 Device related Problems...38 10.3 Poor Performance...39 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 6
Session Details 55 13.6 Step 5 - Creating multiple connections (Optional 56 13.7 Step 6 - Logging off an iSCSI Session 61 14. Glossary ...62 15. Index ...64 Page 4 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 7
Figure 4 Store the label of the library ...11 Figure 5 Remove the blank plate...11 Figure 6 Installing the bridge and store the shipping lock 12 Figure 7 Remove the blank plate on the PowerVault TL4000 12 Figure 8 Installing the bridge in the PowerVault TL4000 13 Figure 9 Remove the second blank - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 8
Session...58 Figure 48 iSCSI bridge Network Configuration Page 59 Figure 49 Showing multiple connections ...60 Figure 50 iSCSI Session with Multiple Connections 61 Page 6 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 9
, and attention notices that are contained in this guide. The user-serviceable components. Only an Authorized Service Center should carry out any servicing or repairs. Unauthorized repairs or modifications will immediately void your warranty. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 10
connectivity between LTO SAS drives installed in a Dell PowerVault TL24iSCSIxSAS and the network. The bridge has been designed to ensure that the majority of installations will require the minimum of set up before use. However, we suggest you read the following as it will guide you through setting - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 11
be blinking when the bridge is ready. LED SAS ports 1, 2, 3 and 4 (Green). Should be blinking when there is port activity. Ethernet port. Air vents. Shipping lock (storage location). SAS port. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 9 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 12
AC connector from the library. Important: Hot plugging is not supported, the unit must be powered off for installation of the iSCSI bridge card. There are ten basic steps to install the iSCSI bridge on the Dell PowerVault TL2000: • Remove the blue label that is securing the lock to the blank plate - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 13
your TL2000 library is without card guide rails for the bridge, please install the card guide rails (reference the Getting Started Guide). • Before . • Lock the bridge in place with two Thumb Screws (see Figure 6 steps 1, 2). Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 14
to installing the iSCSI bridge on the Dell PowerVault TL4000: • Remove the blank plate (see Figure 7) on the rear of the library (you need a #3 Phillips screwdriver). Figure 7 Remove the blank plate on the PowerVault TL4000 Page 12 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 15
8, and Figure 10 step1). Figure 8 Installing the bridge in the PowerVault TL4000 Installing a second bridge in the PowerVault TL4000 with e.g. (four HH SAS Drives). Figure 9 Remove the second blank plate on the PowerVault TL4000 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 13 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 16
Installing the second bridge in the PowerVault TL4000 • Lock the bridge in place with two screws (see Figure 8 and Figure 10 step 2). • Connect the Ethernet cables. • Connect the SAS cables and peripherals. • Connect the library power 14 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 17
Installing the iSCSI support up to 2 SAS connections. Connect the SAS cable to the rear of the iSCSI bridge as shown below, ensuring that connector is oriented correctly. Figure 11 Connect the SAS and network cables in the PowerVault TL2000 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 18
Installing the iSCSI bridge Figure 12 Connect the SAS and network cables in the PowerVault TL4000 Page 16 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 19
to the Dell PowerVault drives and the network as described in the previous sections and power up the unit. From your web browser, connect default password - admin. If the password is entered incorrectly, the following screen will be displayed. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 20
Configuring the iSCSI bridge Figure 14 Invalid Login page Note: We suggest that you change your password at the next possible opportunity - see section 7.4 Page 18 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 21
Configuring the iSCSI bridge The GUI will now display the root selection screen as shown below. Figure 15 Main GUI page Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 19 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 22
with other network clients via their host name. If you have a DNS Server on your network, enter the IP-address in this field. Page 20 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 23
from the server each time it powers up. • Static IP - the IP-address unit will use each time it powers up. Depending on your configuration, either ensure your DHCP-server is set to automatically update the DNS-server. 7.2.5 Setting the Subnet the bridge the user should flush the arp table in their - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 24
. Figure 17 Network Ping page Ping allows the user to send a data packet over a network which will require a response. This is particularly useful to verify the network connections and that a particular network port is visable. Page 22 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 25
a Nework address To send a ping packet to a network address, enter the IP-address in the host field and the number of pings to send. By default 5 pings are sent. Click Ping to send the pings. This will take approximately 5 seconds for 5 pings to complete. A successful ping is shown in Figure 18 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 26
Configuring the iSCSI bridge When a network address is unreachable, the following display will be seen below in Figure 19. If a network port is unreachable 5 pings can take up to 30 seconds to fail. Figure 19 Failed Ping Page 24 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 27
new password into the appropriate boxes and press Change Password. The password can be a maximum of 16 characters. Important: It is not possible to reset the password without logging into the GUI. Ensure you remember your password! Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 28
enter the IP-address for the NTP Server and then click the save button Internet Storage Name Service (iSNS) allows for the automated discovery, management, and configuration of iSCSI devices from a and click the save button. Page 26 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 29
vice versa. When CHAP is enabled, the initiator must send the correct Username and Target Password to gain access to the iSCSI bridge. The Initiator Secret is provided to allow iSCSI mutual and Target Secrets must be different. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 27 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 30
, 3260 and 860. Within the Multipath configuration the user can specify which ports will be made available, 860, 3260 or both. By default, the bridge will allow up to 10 iSCSI connections will limit the number of connections to 1. Page 28 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 31
initiators are configured to automatically reconnect after completing the logout request. If this is the case then the connections window may not show any change. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 29 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 32
Management Page 8.1.1 Global Settings The first option 'Persistent LUN by Device's:' allows the user to select whether SAS Devices are identified by its WWN or SCSI ID for persistency. individual IQNs on the iSCSI interface. Page 30 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 33
to take it out of commission for repair or replacement at a later date without powering down the bridge. IQN - iSCSI Qualified Name iSCSI naming convention that uniquely identifies normally used to refer to the device itself. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 31 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 34
user to monitor the performance, review the error log, import/export a configuration and update the iSCSI bridge's firmware. 9.1 System Information This System information page will allow the user data between the two interfaces. Page 32 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 35
to his local disk, click on 'Click Here to Download'. A popup message will be displayed where the user can specify a meaningful file name and location to save the system log. After setting the file name and path, select save. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 33 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 36
the following window. Figure 27 Saving the configuration page 9.3.1 Import Configuration If the user wishes to load previously saved configuration file, select 'Browse' from within the 'Import to be rebooted to take effect. Page 34 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 37
to the factory defaults. This includes IP-address, hostname and passwords. Note: We strongly recommend that if you return the bridge for maintenance that you reset to defaults to protect passwords and other sensitive information. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 38
allow the user to load new firmware into the bridge. From within the main menu select the Firmware Updates icon from the bridge maintenance section. The GUI will now display the following window. Figure 28 Firmware Update page Page 36 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 39
can be downloaded from the Dell web site at: www.dell.com/support. Once you have downloaded the new firmware to a local disk drive: • Click on the browse button to locate the file you have downloaded from the website. • Then click on the update button. During the update progress of the update can be - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 40
above resolves your problem, then after consulting your Network Administrator, please contact support. 10.2 Device related Problems The iSCSI bridge power up status of libraries is usually displayed on the front panel). • Ensure that the cable between the bridge and the tape drives in the library - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 41
library and bridge. • If none of the above resolves your problem, please contact support poor performance. Within the Link Status Box check the number of TX and RX errors for both network interfaces. This Services\Tcpip\Parameters\ Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 39 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 42
Troubleshooting Add the following DWORD settings: GlobalMaxTcpWindowSize = 0x01400000 TcpWindowSize = 0x01400000 Tcp1323Opts = 3 SackOpts = 1 Note: If controls the GUI has the lowest priority for Network and CPU resources. Page 40 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 43
up your computer for initial set up If your computer is running Windows 95, 98 or NT follow the instructions below. For users with Windows 2000, 2003, XP, 2008 instructions are detailed in Appendix B. In the Network window's Configuration tab, Select the TCP/IP entry. Then the Properties Button - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 44
have completed the initial set up of the iSCSI bridge, return your computer to the original settings and reconnect to the iSCSI bridge. Page 42 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 45
. For users with Windows 95, 98 or NT instructions are detailed in Appendix A. From the Desk Top or Start menu, select My Computer. In the My Computer window select Network and Dial-up Connections positioned in the bottom left hand corner. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 46
the interface connection that will be used to connect to the iSCSI bridge - in this example we have selected the Gigabit Ethernet interface. A general status page will be displayed. From within this page select Properties. Page 44 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 47
: Once you have completed the initial set up of the iSCSI bridge, return your computer to the original settings and reconnect to the iSCSI bridge. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 45 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 48
the user is able to configure the initiator name, specify the initiator secret and set up the IPsec connections. For the purpose of this document we shall leave the initiator name as the default. The iSCSI bridge not support this. Page 46 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 49
of this secret as you will need to enter this as part of configuring CHAPon the iSCSI bridge 13.3 Step 2 - Discovery of Devices Before the user can connect to an iSCSI Target, the iSCSI targets must be discovered. Click on the Discovery tab and you should see a window as in Figure - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 50
the user will want to leave this as default. If multiple network interfaces are installed in the Server and the user wishes to select a particular interface, select the IP-address of that network interface from the pull down list. Page 48 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 51
user iSCSI bridge has had CHAP enabled, or the user wishes to authenticate the iSCSI bridge, click configured on the iSCSI bridge. If the user wishes to authenticate the iSCSI bridge, select of this guide. Once the user is satisfied that all advanced options are correct click OK. The user should now - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 52
to a minute with multiple network ports. Once the discovery is complete, the user should see the target listed in the Target Portals list. See Figure 36. Figure 36 Discovery and discover any iSCSI-Targets that are registered. Page 50 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 53
this example two iSCSI targets have been discovered. The first device is the tape drive, and the second is the media changer. If no devices are displayed, check the settings used to do 39. Figure 39 Connecting to an iSCSI Target Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 51 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 54
the check box 'Automatically restore this connection when the computer starts'. Even if the user wishes to connect to the iSCSI Target using Multipath, they should not check 'Enable 40. Figure 40 Advanced Connection settings. Page 52 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 55
3260. To see how this relates to the iSCSI bridge configuration note the IP-addresses in Figure 41. Figure 41 iSCSI bridge Network Configuration Page Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 53 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 56
discovery phase and click OK. This will now take you back to the window that was shown in figure 10. Click OK once more. The user should now see the iSCSI Target connected. This is shown in Figure 42. Figure 42 iSCSI Target Connected Page 54 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 57
, how many connections are attached to each iSCSI Session, and the Target Portal Group. If the user clicks on the Device tab, he should see details of the target device. Here we can see that the device is an IBM LTO Tape drive. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 55 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 58
iSCSI Target Device 13.6 Step 5 - Creating multiple connections (Optional) If the user wishes to create multiple connections to an iSCSI Session, return to the Session tab shown in Figure 45. Figure 45 Session Connections Page Page 56 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 59
greatest performance increase. If you have been experiencing a performance decrease when transferring data to more than one device using multiple connections, please refer to the trouble shooting guide. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 57 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 60
have connected to 10.10.10.50/3260 as the leading connection and the second connection will be 10.10.11.50/3260. Page 58 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 61
Appendix C The corresponding network configuration on the iSCSI bridge for the example above is shown below in Figure 48. Figure 48 iSCSI bridge Network Configuration Page Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 59 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 62
OK. The user will now be brought back to the window shown in Figure 46. Click OK and now the user should see the Session Connections page with two connections. This is shown in Figure 49. Figure 49 Showing multiple connections Page 60 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 63
Microsoft iSCSI Initiator and click on the Targets tab. • Click on the iSCSI session that the user wishes to log off and then click Details. • In the Target Properties window, select the device should now show as inactive. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 61 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 64
. Data Digest - a code used to insure data integrity of data blocks. Checksums and CRCs are common Firmware - proprietary code that is usually delivered as microcode as part of an operating system. Firmware is more efficient than software Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 65
with thinner and longer cables; its full-duplex signal transmission supports 3.0 Gb/s. In addition, SAS drives can be hotplugged. Subnet-address - the subnet-address is an that insures packets are delivered in order, error free. Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C Page 63 - Dell PowerVault TL4000 | Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS -
User's G - Page 66
Bridge 2, 7, 8, 10, 12, 14, 15, 17, 20, 21, 42, 45 L Login 17 M Maintenance 32, 33, 34, 36 N Network 8, 20, 25, 26, 32 P Password 25, 27 Product view 9 S SAS Bus 15 Service 7, 26 Shipping lock 9 Subnet Mask 21 System Log 33 Page 64 Dell Model TL24iSCSIxSAS 1Gb iSCSI to SAS User's Guide Rev.C
Dell
TM
Model TL24iSCSIxSAS
1Gb iSCSI to SAS
TM
Model TL24iSCSIxSAS 1GBb iSCSI to SAS
www.dell.com
|
support.dell.com