Epson 2070 Service Manual - Page 86
Removing the HP Sensor, 2.5 Removing the PW Sensor Assembly, Removing the HP Sensor,
![]() |
UPC - 010343812277
View all Epson 2070 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Disassembly and Assembly LQ-2070 Service Manual 3.2.4 Removing the HP Sensor 1. Remove the printer cover, ribbon cartridge, front edge guide, and front cover (see Section 3.2.1). 2. Disconnect the connector cable for the HP sensor. 3. Remove the HP sensor by pushing up and releasing the 2 clips at the bottom of the HP sensor from the front paper entrance. 2 Clips for HP Sensor Figure 3-8 Removing the HP Sensor Assembly Note Notice the direction for mounting the HP sensor. 3.2.5 Removing the PW Sensor Assembly 1. Remove the printer cover and ribbon cartridge (see Section 3.2.1). 2. Remove the CB screw (2.5 × 5, F/Zn) securing the PW sensor to the ribbon mask holder. Then, remove the FFC from the PW sensor connector, mounted onto the CR cover. 3. Remove the PW sensor assembly along with the CR cover by pushing and releasing the 2 clips for the CR cover, as shown in the following figure. Figure 3-9 Removing the PW Sensor Assembly 3-8 Rev.A
![](/manual_guide/products/epson-2070-service-manual-3227134/86.png)