Main Menu Functionality, Set the Active Display, Set Active Display Parameters

Page 21 highlights

Main Menu Functionality There are three options on the Main Menu, shown below: hix021.eps Set the Active Display The active display is indicated by the center option on the Main Menu. Push  from this menu to toggle the active display (UPPER, MIDDLE, or LOWER). Set Active Display Parameters To set the parameters of the active display, push  from the Main Menu to go to the Active Display Configuration menu, shown below: Pressure Calibrator Product Features Push  to change to the NEXT active display parameter. Only RTD and Pressure modes have a second parameter. RTDs can be read in Celsius or Fahrenheit. Pressures can be read in 15 engineering units. With a single display, the modes below are available. Push  to access each mode: • [P1] = Pressure internal sensor • [EXT] = Pressure with external pressure module • [P1] ST = Switch Test with left side sensor • [EXT] ST = Switch Test with external pressure module hix022.eps Push  to toggle through the selections for each parameter of the active display. The first parameter is Mode. Since voltage, current, and switch test modes all use the same jacks, two of these functions cannot be used at the same time. The ability to select some functions is limited based on what is already selected on a different display. 11 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Pressure Calibrator
Product Features
11
Main Menu Functionality
There are three options on the Main Menu, shown below:
hix021.eps
Set the Active Display
The active display is indicated by the center option on the
Main Menu. Push
from this menu to toggle the active
display (UPPER, MIDDLE, or LOWER).
Set Active Display Parameters
To set the parameters of the active display, push
from
the Main Menu to go to the Active Display Configuration
menu, shown below:
hix022.eps
Push
to toggle through the selections for each
parameter of the active display. The first parameter is
Mode. Since voltage, current, and switch test modes all
use the same jacks, two of these functions cannot be
used at the same time. The ability to select some
functions is limited based on what is already selected on
a different display.
Push
to change to the NEXT active display parameter.
Only RTD and Pressure modes have a second
parameter. RTDs can be read in Celsius or Fahrenheit.
Pressures can be read in 15 engineering units.
With a single display, the modes below are available.
Push
to access each mode:
[P1] = Pressure internal sensor
[EXT] = Pressure with external pressure module
[P1] ST = Switch Test with left side sensor
[EXT] ST = Switch Test with external pressure
module
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com