Fluke 719PRO-300G Product Manual - Page 64

Error_ Port, Error _ Port?, Func?, Hart_on, Hart_off, Hart?, Hi_err, Hi_err

Page 64 highlights

719PRO Users Manual ERROR_ PORT Sets the pressure port for percent error. For example: To set the pressure port for percent error to [P1], send ERROR_ PORT P1. ERROR _ PORT? Returns the current pressure port for percent error mode. For example: If ERROR _PORT? is sent, it will return P1 if the pressure port in percent error is [P1]. FUNC Sets the display indicated in argument one to the function indicated in argument 2. For example: To set the lower display to RTD mode send FUNC LOWER,RTD. FUNC? Returns the current mode of all displays. For example, if the Product is set to [P2] ST on the upper display, [P1] on the middle, and RTD on the lower, FUNC? returns: ST_P2,P1,RTD 54 HART_ON Turns on the Hart resistor. HART_OFF Turns off the Hart resistor. HART? Returns the state of the Hart resistor. For example: If the Hart resistor was on HART? returns ON. HI_ERR Sets the 100 % point for the percent error mode calculation in the current engineering units. For example: To set the 100 % point to 100 psi, send HI_ERR 100. HI_ERR? Returns the 100 % point for the percent error mode calculation. For example: If the 100 % point is set to 100 psi, HI_ERR? returns 1.000000E+02, PSI. MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

719PRO
Users Manual
54
ERROR_ PORT
Sets the pressure port for percent error.
For example:
To set the pressure port for percent error to [P1], send
ERROR_ PORT P1
.
ERROR _ PORT?
Returns the current pressure port for percent error mode.
For example:
If
ERROR _PORT?
is sent, it will return P1 if the pressure
port in percent error is [P1].
FUNC
Sets the display indicated in argument one to the function
indicated in argument 2.
For example:
To set the lower display to RTD mode send
FUNC
LOWER,RTD
.
FUNC?
Returns the current mode of all displays. For example, if
the Product is set to [P2] ST on the upper display, [P1] on
the middle, and RTD on the lower,
FUNC?
returns:
ST_P2,P1,RTD
HART_ON
Turns on the Hart resistor.
HART_OFF
Turns off the Hart resistor.
HART?
Returns the state of the Hart resistor.
For example:
If the Hart resistor was on
HART?
returns ON.
HI_ERR
Sets the 100 % point for the percent error mode
calculation in the current engineering units.
For example:
To set the 100 % point to 100 psi, send
HI_ERR 100
.
HI_ERR?
Returns the 100 % point for the percent error mode
calculation.
For example:
If the 100 % point is set to 100 psi,
HI_ERR?
returns
1.000000E+02, PSI.