Fluke 719PRO-300G Product Manual - Page 57

Remote Operation

Page 57 highlights

Command LOCAL Description Returns user to manual operation of the Product LOCKOUT Locks out the keypad of the Product in remote operation LO_ERR Sets the 0 % of span limit for percent error mode LO_ERR Returns the 0 % of span limit for percent error mode MOTOR_ON Turns the motor on. MOTOR_OFF Turns the motor off. MOTOR? Returns the current state of the Hart resistor OHMS? OUT Returns ohms value measured from the RTD Set the Product to output the requested current. OUT? Returns the value of the current being simulated. Pressure Calibrator Remote Operation Command Description PRES_UNIT Set the pressure unit for the indicated display PRES_UNIT? Returns the pressure from the indicated display PUMP_LIMIT Sets the approximate value at which the pump will turn off. PUMP_LIMIT? Returns the approximate value at which the pump will turn off. REMOTE Puts the Product in remote mode RTD_TYPE Sets the RTD type RTD_TYPE? Returns the RTD type SIM Set the Product to simulate the requested current. 47 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

Pressure Calibrator
Remote Operation
47
Command
Description
LOCAL
Returns user to manual operation of
the Product
LOCKOUT
Locks out the keypad of the Product in
remote operation
LO_ERR
Sets the 0 % of span limit for percent
error mode
LO_ERR
Returns the 0 % of span limit for
percent error mode
MOTOR_ON
Turns the motor on.
MOTOR_OFF
Turns the motor off.
MOTOR?
Returns the current state of the Hart
resistor
OHMS?
Returns ohms value measured from
the RTD
OUT
Set the Product to output the
requested current.
OUT?
Returns the value of the current being
simulated.
Command
Description
PRES_UNIT
Set the pressure unit for the indicated
display
PRES_UNIT?
Returns the pressure from the
indicated display
PUMP_LIMIT
Sets the approximate value at which
the pump will turn off.
PUMP_LIMIT?
Returns the approximate value at
which the pump will turn off.
REMOTE
Puts the Product in remote mode
RTD_TYPE
Sets the RTD type
RTD_TYPE?
Returns the RTD type
SIM
Set the Product to simulate the
requested current.
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com