HP ML370 ProLiant ML370 Generation 3 Server Maintenance and Service Guide - Page 40
Redundant Fan Cage, Removing the redundant fan cage retaining bracket
UPC - 613326765616
View all HP ML370 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Removal and Replacement Procedures Redundant Fan Cage To remove the optional redundant fan cage: 1. Power down and remove power from the server. Refer to "Powering Down the Server" in this chapter. 2. Unlock and open the front bezel (tower server only). IMPORTANT: You must unlock the tower bezel before removing the access panel. Refer to "Front Bezel" in this chapter. 3. Remove the access panel. Refer to "Access Panel" in this chapter. 4. Remove the fans from the redundant fan cage. Refer to "System Fans" in this chapter. 5. Loosen the two thumbscrews securing the redundant fan cage retaining bracket to the chassis (1). 6. Remove the bracket from the chassis (2). Figure 2-22: Removing the redundant fan cage retaining bracket 7. Remove the redundant fan cage from the chassis. HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide 2-25