HP ML370 ProLiant ML370 Generation 3 Server Maintenance and Service Guide - Page 75

Re-entering the Server Serial Number, System Options, Serial Number, Enter, Escape

Page 75 highlights

Removal and Replacement Procedures Re-entering the Server Serial Number After you replace the system board or clear NVRAM, you must re-enter the server serial number. To re-enter the serial number: During the server startup sequence, press the F9 key to access RBSU. 1. Select the System Options menu. 2. Select Serial Number. The following warning is displayed: WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should ONLY be used by qualified service personnel. This value should always match the serial number sticker located on the chassis. Press the Enter key to clear the warning. 3. Enter the serial number and press the Enter key. 4. Press the Escape key to close the menu. 5. Press the Escape key to exit RBSU. 6. Press the F10 key to confirm exiting RBSU. The server will automatically reboot. 2-60 HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113

Removal and Replacement Procedures
2-60
HP ProLiant ML370 Generation 3 Server Maintenance and Service Guide
Re-entering the Server Serial Number
After you replace the system board or clear NVRAM, you must re-enter the server serial
number. To re-enter the serial number:
During the server startup sequence, press the
F9
key to access RBSU.
1. Select the
System Options
menu.
2. Select
Serial Number
. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the
Enter
key to clear the warning.
3.
Enter the serial number and press the
Enter
key.
4. Press the
Escape
key to close the menu.
5. Press the
Escape
key to exit RBSU.
6. Press the
F10
key to confirm exiting RBSU. The server will automatically reboot.