HP P Class 450/500/550/600/650/700/750 DiagTools User's Guide - Page 53
h - 00CCh, System Error Codes
View all HP P Class 450/500/550/600/650/700/750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Appendix A The Error Codes 0001h - 00CCh: System Error Codes 0001h - 00CCh: System Error Codes Code 0001h 0002h 0003h 0004h 0005h 0006h 0007h 0008h Explanation Details/Parts to Check Cannot load the MSW (Machine Status Word). Processor error. Check that the processor is correctly installed. If the error persists, install new processor. Cannot load the GDT (Global Descriptor Table) Register. Processor error. Check that the processor is correctly installed. If the error persists, install new processor. Cannot load the IDT (Interrupt Descriptor Processor error. Table) Register. Check that the processor is correctly installed. If the error persists, install new processor. ARPL instruction execution error. Processor error. Check that the processor is correctly installed. If the error persists, install new processor. LAR (Load Access Rights Byte) instruction Processor error. execution error. Check that the processor is correctly installed. If the error persists, install new processor. LSL (Load Segment Limit) instruction execution error. Processor error. Check that the processor is correctly installed. If the error persists, install new processor. VERR (Verify a Segment for Reading) instruction execution error. Processor error. Check that the processor is correctly installed. If the error persists, install new processor. VERW (Verify a Segment for Writing) instruction execution error. Processor error. Check that the processor is correctly installed. If the error persists, install new processor. English 43