HP P Class 450/500/550/600/650/700/750 DiagTools User's Guide - Page 76
Infrared register test failed at port
View all HP P Class 450/500/550/600/650/700/750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Appendix A The Error Codes 0601h - 0617h: Serial Port Error Codes Code 0609h 0610h 0611h 0612h 0613h 0614h 0615h 0616h 0617h Explanation FIFO trigger level test failed at port XXXXh. FIFO character timeout indication test failed at port XXXXh. FIFO data transfer test failed at port XXXXh. Baud rate speed test failed. Infrared register test failed at port XXXXh. Infrared interrupt ID test failed at port XXXXh. Infrared internal loopback test failed at port XXXXh. Infrared line status test failed at port XXXXh. Infrared data transfer test failed at port XXXXh. Details/Parts to Check Serial port controller error. Install new system board. Serial port controller error. Install new system board. Serial port controller error. Install new system board. If the test is running on a 16650 UART, check the frequency selected in the test menu matches the jumper settings on the card. Re-run the diagnostics test. Serial port controller error. Install new system board. Serial port controller error. Install new system board. Serial port controller error. Install new system board. Serial port controller error. Install new system board. Serial port controller error. Install new system board. 66 English