HP P Class 450/500/550/600/650/700/750 DiagTools User's Guide - Page 59
Motherboard has no EISA ID
View all HP P Class 450/500/550/600/650/700/750 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
Appendix A The Error Codes 0001h - 00CCh: System Error Codes Code 0090h 0091h 0094h 0095h 0096h 0097h 0098h 0099h 009Ah 009Bh 009Ch 009Dh 009Eh 009Fh 00A0h 00A1h Explanation PnP function 00 failed. PnP function 01 failed. Number of system device nodes is not the same as reported. One or more nodes have larger than reported size. ISA bus detected twice. No EISA bus system device node Motherboard has no EISA ID One or more EISA slots are not configured. PnP function 40 failed. Invalid number of PnP cards. One or more unknown PnP cards. No PCI bus system device node. Too many PCI buses. Insufficient memory. PnP function 41 failed. NVRam buffer size too big. 00A2h ESCD size is too small. 00A3h ESCD size is too big. Details/Parts to Check Install new system BIOS. Install new system BIOS. Install new system BIOS. If error persists, install new system board. Check all PnP devices. Install new system BIOS. Install new system BIOS. Install new system BIOS. Run the ECU, and then re-run DiagTools. If error persists, install new system BIOS. Install new system BIOS. Check all PnP devices. Install new system BIOS. Install new system BIOS. Install new system BIOS. Delete drivers before running DiagTools. Install new system BIOS. Install new system BIOS. If error persists, install new system board. Install new system BIOS. If error persists, install new system board. Install new system BIOS. If error persists, install new system board. English 49