HP ProLiant DL980 HP ProLiant Servers Troubleshooting Guide - Page 43
Drive problems hard drives and solid state drives
View all HP ProLiant DL980 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Drive is not found Action: Be sure no loose connections (on page 18) exist with the drive. Non-system disk message is displayed Action: 1. Remove the non-system diskette from the drive. 2. Check for and disconnect any non-bootable USB devices. Diskette drive cannot write to a diskette Action: 1. If the diskette is not formatted, format the diskette. 2. Be sure the diskette is not write protected. If it is, use another diskette or remove the write protection. 3. Be sure you are attempting to write to the proper drive by checking the drive letter in the path statement. 4. Be sure enough space is available on the diskette. Drive problems (hard drives and solid state drives) HP SIM reports a drive fault on a parallel SCSI hard drive managed by an HP Smart Array controller Action: • If the drive fault LED is illuminated, see the drive LED combination tables in "Hard drive LED combinations (on page 20)." • If the drive fault LED is flashing, replace the hard drive. See the server maintenance and service guide. • If the drive fault LED is not flashing and the operating system supports HP Insight Diagnostics, version 7.40 or later ("HP Insight Diagnostics" on page 75), perform the following: a. Run the Smart Array SCSI Diagnosis feature (on page 75). b. Perform the actions recommended by the diagnosis report. c. If the issue is still present, run ADU, version 7.31 or later ("Array diagnostic software" on page 76). For ADU report analysis, contact HP support ("Contacting HP" on page 173). • If the drive fault LED is not flashing and the operating system does not support HP Insight Diagnostics, version 7.40 or later ("HP Insight Diagnostics" on page 75), insert the SmartStart CD and run ADU, version 7.31 or later ("Array diagnostic software" on page 76). For ADU report analysis, contact HP support ("Contacting HP" on page 173). The fault LED is illuminated on a parallel SCSI hard drive managed by an HP Smart Array controller Action: Hardware problems 43
-
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
12
-
13
-
14
-
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
26
-
27
-
28
-
29
-
30
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
65
-
66
-
67
-
68
-
69
-
70
-
71
-
72
-
73
-
74
-
75
-
76
-
77
-
78
-
79
-
80
-
81
-
82
-
83
-
84
-
85
-
86
-
87
-
88
-
89
-
90
-
91
-
92
-
93
-
94
-
95
-
96
-
97
-
98
-
99
-
100
-
101
-
102
-
103
-
104
-
105
-
106
-
107
-
108
-
109
-
110
-
111
-
112
-
113
-
114
-
115
-
116
-
117
-
118
-
119
-
120
-
121
-
122
-
123
-
124
-
125
-
126
-
127
-
128
-
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
141
-
142
-
143
-
144
-
145
-
146
-
147
-
148
-
149
-
150
-
151
-
152
-
153
-
154
-
155
-
156
-
157
-
158
-
159
-
160
-
161
-
162
-
163
-
164
-
165
-
166
-
167
-
168
-
169
-
170
-
171
-
172
-
173
-
174
-
175
-
176
-
177
-
178
-
179
-
180
-
181
-
182
-
183
-
184
-
185
-
186
-
187
-
188
-
189
-
190