Removing a PCI-X Smart Fan Assembly, CAUTION, PCI-X Smart Fan Assembly Location
View all HP Server rp7420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions can result in damage to the server. Figure 6-14 PCI-X Smart Fan Assembly Location Table 6-3 Smart Fan Assembly LED Indications LED State Description On Green Fan is at speed and in sync or not at speed less than six seconds Flashing Yellow Fan is not keeping up with speed/sync pulse for greater than six seconds Flashing Red Fan failed or stalled or has run slow or fast for greater than six seconds Off Fan is not installed or no power is applied to fan Removing a PCI-X Smart Fan Assembly Figure 6-15 PCI-X Smart Fan Assembly Detail To remove a PCI-X smart fan assembly, follow these steps: 1. Remove the top cover. 96 Removing and Replacing Server Components