Managing the HP SureStore E Disk Array 12H on MPE Configuring AutoRAID SCSI LUNs for MPE/iX MPE/iX SYSGEN Configuration The following example illustrates how to configure an MPE/iX logical device (LDEV) to a SCSI LUN. It assumes the configuration of an LDEV to a physical I/O path of 10/16/4.1.0. NOTE! To obtain the path, use the offline utility ODE and run mapper. To configure any device on an MPE/iX system, use the SYSGEN configuration from the MPE/iX system prompt as follows: :SYSGEN Within the IO area of SYSGEN, configure the upper level hardware first. For example, a 969KS/100 has two levels of bus converters, which appear in the path prior to specifying the HP-PB slot number. The following is a SYSGEN list path(lp) from the io prompt: io> lp 10 PATH: 10 LDEV: ID: A2372-6003 TYPE: BC PMGR: BUS_CONV_MGR PMGRPRI: 2 LMGR: MAXIOS: 0 io> lp 10/16 PATH: 10/16 ID: A2372-60003 PMGR: BUS_CONV_MGR LMGR: LDEV: TYPE: BC PMGRPRI: 2 MAXIOS: 0 MPE 122