HP Surestore Disk Array 12h System Administrator's Guide for HP-UX, MPE, and W - Page 57

To set the data resiliency mode, type, Table 7. Data Resiliency Settings, Setting, Description

Page 57 highlights

HP-UX Using the ARM Command Line Utilities for HP-UX Performing Disk Array Maintenance Tasks To set the data resiliency mode, type: arraymgr -J {SingleController | Secure | Normal | HighPerformance} The data resiliency settings are described in Table 7. Setting SingleController Secure Normal HighPerformance Table 7. Data Resiliency Settings Description This setting should only be used if the disk array is operating with one controller. This suppresses the single controller warning messages that are normally generated when the disk array is operating with one controller. This setting will affect I/O performance. This is the default setting for single controller mode. Continually updates the disks with any changes in the controller maps. This is the highest level of data protection, but it may result in decreased I/O performance. Updates the maps on the disks at regular intervals (typically 4 seconds). This option offers both data protection and good performance. This is the default setting for dual controller mode. Updates the disk maps only during shutdown of the disk array. This is the lowest level of data protection, but it offers the highest level of performance. 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279

Using the ARM Command Line Utilities for HP-UX
Performing Disk Array Maintenance Tasks
57
HP-UX
To set the data resiliency mode, type:
arraymgr -J {SingleController | Secure | Normal | HighPerformance} <array-id
>
The data resiliency settings are described in
Table 7
.
Table 7. Data Resiliency Settings
Setting
Description
SingleController
This setting should only be used if the disk array is operating with one
controller. This suppresses the single controller warning messages that
are normally generated when the disk array is operating with one
controller. This setting will affect I/O performance. This is the default
setting for single controller mode.
Secure
Continually updates the disks with any changes in the controller maps.
This is the highest level of data protection, but it may result in
decreased I/O performance.
Normal
Updates the maps on the disks at regular intervals (typically 4 seconds).
This option offers both data protection and good performance. This is
the default setting for dual controller mode.
HighPerformance
Updates the disk maps only during shutdown of the disk array. This is
the lowest level of data protection, but it offers the highest level of
performance.