HP Surestore Disk Array 12h System Administrator's Guide for HP-UX, MPE, and W - Page 225

Changing Disk Array Configuration Settings, Using AutoRAID Manager for Windows NT, Properties, Status

Page 225 highlights

Using AutoRAID Manager for Windows NT Changing Disk Array Configuration Settings To check disk array status: 1. Right-click the disk array from the Detail pane. 2. Click Properties. 3. Click the Status tab. NOTE! Double clicking on a disk array entry in the Array List window has the same effect as rightclicking the array. Changing Disk Array Configuration Settings A number of configuration settings control the operation of the disk array. These settings are usually established during installation and, once set, should rarely need to be changed. The default settings have been selected to provide the best operation for most systems. However, if you determine that any setting does not meet your needs, you can easily change it. Table 26 lists the various settings, including factors you may want to consider before changing them. Setting Active Spare Auto Rebuild Auto Include Rebuild Priority Table 26. Disk Array Configuration Settings Default On On On High Comments and Considerations Active Hot Spare provides optimum protection against disk failure. Disabling Active Hot Spare will make additional capacity available to the host, but at the expense of not maintaining data redundancy in the event of a disk failure. Auto Rebuild provides optimum protection against disk failure by rebuilding a failed disk as quickly as possible. Disabling Auto Rebuild gives you more control over the rebuild process, but it can leave the disk array vulnerable to a second disk failure until a rebuild is performed manually. Auto Include simplifies the task of adding a new disk to your array. Disabling it will require you manually to include each disk you install in the array. Rebuild priority determines how quickly a rebuild operation will complete. Windows NT 225

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279

Using AutoRAID Manager for Windows NT
Changing Disk Array Configuration Settings
225
Windows NT
To check disk array status:
1.
Right-click the disk array from the Detail pane.
2.
Click
Properties
.
3.
Click the
Status
tab.
NOTE!
Double clicking on a disk array entry in the Array List window has the same effect as right-
clicking the array.
Changing Disk Array Configuration Settings
A number of configuration settings control the operation of the disk array. These settings are usually
established during installation and, once set, should rarely need to be changed.
The default settings have been selected to provide the best operation for most systems. However, if you
determine that any setting does not meet your needs, you can easily change it.
Table 26
lists the various settings, including factors you may want to consider before changing them.
Table 26. Disk Array Configuration Settings
Setting
Default
Comments and Considerations
Active
Spare
On
Active Hot Spare provides optimum protection against disk
failure. Disabling Active Hot Spare will make additional capacity
available to the host, but at the expense of not maintaining data
redundancy in the event of a disk failure.
Auto
Rebuild
On
Auto Rebuild provides optimum protection against disk failure by
rebuilding a failed disk as quickly as possible. Disabling Auto
Rebuild gives you more control over the rebuild process, but it can
leave the disk array vulnerable to a second disk failure until a
rebuild is performed manually.
Auto
Include
On
Auto Include simplifies the task of adding a new disk to your
array. Disabling it will require you manually to include each disk
you install in the array.
Rebuild
Priority
High
Rebuild priority determines how quickly a rebuild operation will
complete.