HP Surestore Disk Array 12h System Administrator's Guide for HP-UX, MPE, and W - Page 92
Operational Command Descriptions, The RECOVER command allows the user to restore controller map information in the specified SureStore, E AutoRAID Disk Array.
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
HP-UX Using the ARDIAG Offline Diagnostic on HP-UX Operational Command Descriptions RECOVER The RECOVER command allows the user to restore controller map information in the specified SureStore E (AutoRAID) Disk Array. Synopsis RECOVER Output ARDIAG>testdisk 1 Array state is No Address Table The following warnings are currently in effect: Disk Warning Capacity Warning ARDIAG>testlevel 0 TESTLEVEL = 0 ARDIAG> recover The logs should be cleared before executing this command. Do you want to abort to clear logs ([y]/n)? no There is only one volume set in the array. 0) " 125B0 D") Disks: A1 A2 A3 Proceed with recover operation ([y]/n)? yes Recovery Progress = 1 Percent Recovery Progress = 2 Percent Recovery Progress = 3 Percent . . . 92
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-administrators-guide-hpux-mpe-windows-nt-2be7e4f/92.png)
Using the ARDIAG Offline Diagnostic on HP-UX
Operational Command Descriptions
92
HP-UX
RECOVER
The RECOVER command allows the user to restore controller map information in the specified SureStore
E (AutoRAID) Disk Array.
Synopsis
RECOVER
Output
ARDIAG>testdisk 1
Array state is No Address Table
The following warnings are currently in effect:
Disk Warning
Capacity Warning
ARDIAG>testlevel 0
TESTLEVEL = 0
ARDIAG> recover
The logs should be cleared before executing this command.
Do you want to abort to clear logs ([y]/n)? no
There is only one volume set in the array.
0)
"
125B0
D")
Disks: A1
A2
A3
Proceed with recover operation ([y]/n)? yes
Recovery Progress = 1 Percent
Recovery Progress = 2 Percent
Recovery Progress = 3 Percent
.
.
.