HP Surestore Disk Array 12h System Administrator's Guide for HP-UX, MPE, and W - Page 123
Device Adapter Configuration, SCSI Target Configuration, User's and Service Manual
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
MPE Managing the HP SureStore E Disk Array 12H on MPE Configuring AutoRAID SCSI LUNs for MPE/iX Device Adapter Configuration: Configure the HP-PB Fast/Wide SCSI adapter using the SYSGEN ID of HP28696: io> ap 10/16/4 id = hp28696a io> lp 10/16/4 PATH: 10/16/4 LDEV: ID: HP28696A TYPE: DA PMGR: FWSCSI_DAM PMGRPRI: 6 LMGR: MAXIOS: 0 SCSI Target Configuration: The next item to configure is the SCSI Target ID (TID). Since the AutoRAID is a multi-lun device, the TID will be the same for each LDEV connected to any single AutoRAID. The SCSI Target will represent the path to the controller that the SCSI cable is connected to. NOTE: The setting of the initial SCSI TARGET(TID) and the SCSI LUN values on the AutoRAID can be set by the front panel control. See User's and Service Manual for information on how to use the front panel. The SCSI Target ID of the controller is represented within SYSGEN using the ID of PSEUDO. io> ap 10/16/4.1 id=pseudo io> lp 10/16/4/1 PATH: 10/16/4/1 LDEV: ID: PSEUDO TYPE: DA PMGR: TRANSPARENT_MGR PMGRPRI: 6 LMGR: MAXIOS: 0 123