HP Surestore Disk Array 12h System Administrator's Guide for HP-UX, MPE, and W - Page 162
Table 22. Simplified Data Resiliency Settings, Normal Mode, Parameter, Default, Setting, Simplified
![]() |
View all HP Surestore Disk Array 12h manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 162 highlights
MPE Using the ARM Command Line Utilities for MPE Viewing the Disk Array General Configuration Settings Table 22. Simplified Data Resiliency Settings Normal Mode Parameter Default Setting Single Controller ENABLED Warning Lock Write Cache On TRUE Disable NVRAM on FALSE WCE False Disable NVRAM with TRUE One Ctrlr Disable NVRAM on FALSE UPS absent Force Unit Access 2 Response Disable Read Hits FALSE Resiliency Threshold 4 SingleController Mode Simplified Resiliency Setting Results Single Controller Dual Controller Not Supported Data map and write cache information will be flushed to the disk every four seconds. Parameter Default Setting Simplified Resiliency Setting Results Single Controller DISABLED Warning Single Controller Lock Write Cache On FALSE Data map and write cache Disable NVRAM on TRUE information will be flushed WCE False Disable NVRAM with TRUE to the disk once every second. One Ctrlr Disable NVRAM on FALSE UPS absent Force Unit Access 2 Response Disable Read Hits FALSE Resiliency Threshold 1 Dual Controller Not Supported 162
![](/manual_guide/products/hewlettpackard-surestore-disk-array-12h-administrators-guide-hpux-mpe-windows-nt-2be7e4f/162.png)