HP c3700 hp Visualize b2000 UNIX workstation service handbook (a5983-90039) - Page 88
Left Side Panel
View all HP c3700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Field Replaceable Units FRU Removal and Replacement Left Side Panel This section explains how to open and close the left side panel. You will need to open this side panel whenever you need to access the internal components of the workstation. Opening the Left Side Panel Perform the following steps to open the left side panel: 1. Power off the workstation and unplug the power cord from the electrical outlet. WARNING Always unplug the workstation's power cord from the electrical outlet before opening the workstation. 2. Attach the static-grounding wrist strap by following the instructions on the package. Attach the sticky end of the wrist strap to bare metal on the workstation's rear panel. 3. Remove the two T-15 Torx thumbscrews located on the top and bottom, right edge of the workstation's rear panel, as shown in Figure 4-3. 4. Grasp the rear edge of the left side panel and rotate it outward approximately 30 degrees to the workstation. Next, pull the panel toward you as shown in Figure 4-3. This releases the panel's top and bottom hinge hooks from their hinge slots. Figure 4-3. Opening the Left Side Panel Hinge Hook T-15 Torx Thumbscrew EMI Gasket T-15 Torx Thumbscrew Hinge Hook Left Side Panel NOTE The EMI gasket, as shown in Figure 4-3, must not be removed from the left side panel. 88 Chapter 4