Table 2. Symptom-to-FRU index for front view LEDs (continued) Symbol Problem Indicator Action Amber Storage Subsystem Fault LED is lit solidly. If the fault LED is lit continuously (not flashing), there is a problem with the storage subsystem. Use the ServeRAID Manager program to diagnose and repair the problem. For more information, see the DS300 and DS400 Problem Determination Guide. One of more of the following conditions might exist: v Power supply fault v Fan fault v Overtemperature fault v RAID controller module fault v Battery fault v Cache DIMM fault v XScale DIMM fault v Disk drive fault v Turned ON through SES control page 1. Check the LEDs for all components on enclosure (disk drives, power supplies, controllers) and follow the solution instructions provided for the respective illuminated LED. 2. If no other fault LED is on, replace the controller: v DS300 1-RS (p/n 13N1894) v DS300 1-RL (p/n 13N1895) 3. If replacing the controller does not resolve the issue, replace the chassis/backplane assembly (p/n 13N1786). Amber Storage Subsystem Fault LED is lit flashing. When this LED is lit flashing, it indicates that an illegal hardware configuration is detected. Verify that the RAID controller and power supply are both installed in the slot A side. Note: This should only occur with the DS300 type 1701 (model 1RL. No label Green Hard disk drive activity LED is off. Start your application and verify that the activity No drive activity is being detected. LED flashes as the drive is accessed. No label Amber Hard Disk Drive Status LED is lit solidly. Each hard disk drive has a status LED. When this LED is lit solidly, it indicates that the drive has failed. Note: When this LED is flashing slowly (one flash per second), it indicates that the drive is being rebuilt. When the LED is flashing rapidly (three flashes per second), it indicates that the RAID controller is identifying the drive. For a single drive failure, replace the failed drive. For a multiple drive failure, attempt to determine the order in which the drives failed and then follow the appropriate recovery process for their RAID level. For additional information on troubleshooting drive-side issues, refer to the Drive Side PD Map in the DS300 and DS400 Problem Determination Guide. Table 3. Symptom-to-FRU index for power supply LEDs Symbol Problem Indicator Green Power Supply Power LED is off. Action Verify that the power cord is plugged in and that the storage subsystem power is on. 14 IBM TotalStorage DS300 and DS400: Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

Table
2.
Symptom-to-FRU
index
for
front
view
LEDs
(continued)
Symbol
Problem
Indicator
Action
Amber
Storage
Subsystem
Fault
LED
is
lit
solidly.
If
the
fault
LED
is
lit
continuously
(not
flashing),
there
is
a
problem
with
the
storage
subsystem.
Use
the
ServeRAID
Manager
program
to
diagnose
and
repair
the
problem.
For
more
information,
see
the
DS300
and
DS400
Problem
Determination
Guide
.
One
of
more
of
the
following
conditions
might
exist:
v
Power
supply
fault
v
Fan
fault
v
Overtemperature
fault
v
RAID
controller
module
fault
v
Battery
fault
v
Cache
DIMM
fault
v
XScale
DIMM
fault
v
Disk
drive
fault
v
Turned
ON
through
SES
control
page
1.
Check
the
LEDs
for
all
components
on
enclosure
(disk
drives,
power
supplies,
controllers)
and
follow
the
solution
instructions
provided
for
the
respective
illuminated
LED.
2.
If
no
other
fault
LED
is
on,
replace
the
controller:
v
DS300
1-RS
(p/n
13N1894)
v
DS300
1-RL
(p/n
13N1895)
3.
If
replacing
the
controller
does
not
resolve
the
issue,
replace
the
chassis/backplane
assembly
(p/n
13N1786).
Amber
Storage
Subsystem
Fault
LED
is
lit
flashing.
When
this
LED
is
lit
flashing,
it
indicates
that
an
illegal
hardware
configuration
is
detected.
Verify
that
the
RAID
controller
and
power
supply
are
both
installed
in
the
slot
A
side.
Note:
This
should
only
occur
with
the
DS300
type
1701
(model
1RL.
No
label
Green
Hard
disk
drive
activity
LED
is
off.
No
drive
activity
is
being
detected.
Start
your
application
and
verify
that
the
activity
LED
flashes
as
the
drive
is
accessed.
No
label
Amber
Hard
Disk
Drive
Status
LED
is
lit
solidly.
Each
hard
disk
drive
has
a
status
LED.
When
this
LED
is
lit
solidly,
it
indicates
that
the
drive
has
failed.
Note:
When
this
LED
is
flashing
slowly
(one
flash
per
second),
it
indicates
that
the
drive
is
being
rebuilt.
When
the
LED
is
flashing
rapidly
(three
flashes
per
second),
it
indicates
that
the
RAID
controller
is
identifying
the
drive.
For
a
single
drive
failure,
replace
the
failed
drive.
For
a
multiple
drive
failure,
attempt
to
determine
the
order
in
which
the
drives
failed
and
then
follow
the
appropriate
recovery
process
for
their
RAID
level.
For
additional
information
on
troubleshooting
drive-side
issues,
refer
to
the
Drive
Side
PD
Map
in
the
DS300
and
DS400
Problem
Determination
Guide
.
Table
3.
Symptom-to-FRU
index
for
power
supply
LEDs
Symbol
Problem
Indicator
Action
Green
Power
Supply
Power
LED
is
off.
Verify
that
the
power
cord
is
plugged
in
and
that
the
storage
subsystem
power
is
on.
14
IBM
TotalStorage
DS300
and
DS400:
Hardware
Maintenance
Manual