IBM 17011RS Maintenance Manual - Page 54

Replacing, round, lithium, battery, controller

Page 54 highlights

c. Lift the drive partially out of the bay and wait at least 20 seconds before fully removing the drive from the storage subsystem. This enables the drive to spin down and avoids possible damage to the drive. d. Make sure that there is proper identification (such as a label) on the hard disk drive; then, gently slide it completely out of the storage subsystem. 5. Install the new hard disk drive: a. Gently push the drive into the empty bay until the tray handle touches the storage subsystem tray. b. Push down the tray handle into the closed (latched) position. 6. Check the hard disk drive LEDs. v When a drive is ready for use, the green activity LED and the amber status LED are off. v If the amber status LED is lit and not flashing, remove the drive from the unit and wait 10 seconds; then, reinstall the drive. If the amber LED is flashing, the drive is being rebuilt. ServeRAID information: In some cases, the ServeRAID Manager program will automatically reset the drive to the Hot Spare or Rebuild state. If the drive-state change does not occur automatically (amber LED stays lit), see the ServeRAID Manager program online help for information about changing the state of the drive from the current state to another state, such as Hot Spare or Ready. The amber LED turns off within 10 seconds after the drive-state change. Replacing the round lithium battery in the RAID controller When replacing the round lithium battery, you must replace it with a lithium battery of the same type. To order replacement batteries, call 1-800-426-7378 within the United States, and 1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your IBM reseller or IBM marketing representative. Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 46H4132 or an equivalent type battery. If your system has a module containing a lithium battery, replace it only with the same module type. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not: v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble Dispose of the battery as required by local ordinances or regulations. 40 IBM TotalStorage DS300 and DS400: Hardware Maintenance Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

c.
Lift
the
drive
partially
out
of
the
bay
and
wait
at
least
20
seconds
before
fully
removing
the
drive
from
the
storage
subsystem.
This
enables
the
drive
to
spin
down
and
avoids
possible
damage
to
the
drive.
d.
Make
sure
that
there
is
proper
identification
(such
as
a
label)
on
the
hard
disk
drive;
then,
gently
slide
it
completely
out
of
the
storage
subsystem.
5.
Install
the
new
hard
disk
drive:
a.
Gently
push
the
drive
into
the
empty
bay
until
the
tray
handle
touches
the
storage
subsystem
tray.
b.
Push
down
the
tray
handle
into
the
closed
(latched)
position.
6.
Check
the
hard
disk
drive
LEDs.
v
When
a
drive
is
ready
for
use,
the
green
activity
LED
and
the
amber
status
LED
are
off.
v
If
the
amber
status
LED
is
lit
and
not
flashing,
remove
the
drive
from
the
unit
and
wait
10
seconds;
then,
reinstall
the
drive.
If
the
amber
LED
is
flashing,
the
drive
is
being
rebuilt.
ServeRAID
information:
In
some
cases,
the
ServeRAID
Manager
program
will
automatically
reset
the
drive
to
the
Hot
Spare
or
Rebuild
state.
If
the
drive-state
change
does
not
occur
automatically
(amber
LED
stays
lit),
see
the
ServeRAID
Manager
program
online
help
for
information
about
changing
the
state
of
the
drive
from
the
current
state
to
another
state,
such
as
Hot
Spare
or
Ready.
The
amber
LED
turns
off
within
10
seconds
after
the
drive-state
change.
Replacing
the
round
lithium
battery
in
the
RAID
controller
When
replacing
the
round
lithium
battery,
you
must
replace
it
with
a
lithium
battery
of
the
same
type.
To
order
replacement
batteries,
call
1-800-426-7378
within
the
United
States,
and
1-800-465-7999
or
1-800-465-6666
within
Canada.
Outside
the
U.S.
and
Canada,
call
your
IBM
reseller
or
IBM
marketing
representative.
Statement
2:
CAUTION:
When
replacing
the
lithium
battery,
use
only
IBM
Part
Number
46H4132
or
an
equivalent
type
battery.
If
your
system
has
a
module
containing
a
lithium
battery,
replace
it
only
with
the
same
module
type.
The
battery
contains
lithium
and
can
explode
if
not
properly
used,
handled,
or
disposed
of.
Do
not:
v
Throw
or
immerse
into
water
v
Heat
to
more
than
100°C
(212°F)
v
Repair
or
disassemble
Dispose
of
the
battery
as
required
by
local
ordinances
or
regulations.
40
IBM
TotalStorage
DS300
and
DS400:
Hardware
Maintenance
Manual