IBM 17011RS Maintenance Manual - Page 38
Fibre, Channel, controller, Power, supply
![]() |
UPC - 000435304971
View all IBM 17011RS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Power supplies Fibre Channel RAID controllers Figure 13. DS400 storage subsystem model 1700-2RD rear view Fibre Channel RAID controller The DS400 storage subsystem comes with one or two Fibre Channel RAID controllers. Each Fibre Channel RAID controller has one 1 Gb/sec (gigabit per second) Ethernet connector for management, two 2 Gb/sec Fibre Channel host ports, and 12 LEDs. If the storage subsystem comes with only one RAID controller, there is a filler panel in the right RAID controller bay (side B). The filler panel must remain in place to maintain proper cooling. Each RAID controller also contains a battery to maintain cache data in the event of a power failure. For more information, see "Cache memory and RAID controller battery" on page 26.. Power supply The DS400 storage subsystem contains two hot-swap power supplies. Each unit is a self-contained power supply with three integral cooling fans, a power switch, and two status LEDs. Storage subsystem controls and LEDs The following sections show the DS400 storage subsystem controls and LEDs. Front view The following illustration shows the LEDs on the front of the DS400 storage subsystem. Power-on LED Locator LED Storage subsystem fault LED Hard disk drive activity LED Hard disk drive status LED Figure 14. DS400 storage subsystem front LEDs 24 IBM TotalStorage DS300 and DS400: Hardware Maintenance Manual
![](/manual_guide/products/ibm-17011rs-maintenance-manual-ccee445/38.png)