and 10 on page 50 for the procedure to replace the 512 MB system DIMM on the replacement controller with the 1 GB system DIMM from the failed controller. 11. Install the replacement controller: a. Make sure that the lever on each side of the controller is down as far as it will go. b. Push the controller into the bay until it meets resistance (approximately 6 mm [0.25 in.] from the end of the chassis). c. While squeezing together the latch and lever, push both latches up as far as they will go. The controller slides the rest of the way into the bay. 12. Reconnect the Ethernet cables that were disconnected in step 3 on page 49. 13. For a Fibre Channel RAID controller only: Insert the SFP modules and fiber-optic cables that you removed in step 4 on page 49. 14. Turn on the storage subsystem if you turned it off in step 1 on page 49. Configuring the management port To configure the management port, complete the following steps: 1. Open a Telnet session: v For a single-controller DS300 or DS400: Open a Telnet session to the default IP address 192.168.70.123. v For a dual-controller DS300 or DS400: Open a Telnet session to the IP address of the active controller. 2. At the command prompt, enter administrator. 3. At the password prompt, enter your administrator password. Note: The default administrator password is passw0rd (all lowercase letters with a zero, not O, in passw0rd). Complete the following two steps for a dual-controller DS300 or DS400 storage subsystem only: 4. At the command prompt, enter controller peer enable. 5. To determine whether the peer controller is ready, enter controller information. The peer controller is working correctly if the peer controller status is Ready. 6. For all storage subsystems: When the peer controller is ready, change the IP address and netmask address of the replacement controller to match your previous management port settings: v For a single-controller DS300 or DS400: To change the IP address, enter interface manage eth0 ip IP_address_of_failed_controller To change the netmask address, enter interface manage eth0 netmask network_mask_of_failed_controller Note: For a single-controller storage subsystem, when you change the IP address for the management port, you must establish a new Telnet session to the new IP address. v For a dual-controller DS300 or DS400: To change the IP address, enter interface manage eth0[x] ip IP_address_of_failed_controller To change the netmask address, enter interface manage eth0[x] netmask network_mask_of_failed_controller Appendix A. Installing and replacing components 51
![](/manual_guide/products/ibm-17011rs-maintenance-manual-ccee445/65.png)