Position the server bracket on the, Tighten the screws.
UPC - 087944475767
View all IBM 86605SU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 242 highlights
7. Tighten all screws to secure both slide-bracket assemblies. If you are using a torque screwdriver, use the following torque setting: 8-11 Nm (70.8-97.0 in/lbs). 8. Attach the cable-management arm to the rear of the rack: a. Position the cable-management arm bracket on the outside of the mounting rail. b. Insert screws (M6 by 16 mm) through the cable-management arm bracket, mounting rail, and cage nuts. Tighten the screws. c. Position the server bracket on the cable-management arm. d. Insert screws through the cable-management arm and the server bracket. Attach M6 hex nuts to the screws and tighten the hex nuts. Netfinity 5500 - Type 8660 237
7.
Tighten all screws to secure both slide-bracket
assemblies.
If you are using a torque screwdriver,
use the following torque setting: 8–11
Nm (70.8–97.0
in/lbs).
8.
Attach the cable-management arm to the rear of the
rack:
a.
Position the cable-management arm bracket on
the outside of the mounting rail.
b.
Insert screws (M6 by 16
mm) through the
cable-management arm bracket, mounting rail,
and cage nuts.
Tighten the screws.
c.
Position the server bracket on the
cable-management arm.
d.
Insert screws through the cable-management
arm and the server bracket.
Attach M6 hex nuts
to the screws and tighten the hex nuts.
Netfinity 5500 - Type 8660
237