IBM 86605SU Maintenance Manual - Page 275
Error Code/Symptom, DIMM Location J2
![]() |
UPC - 087944475767
View all IBM 86605SU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 275 highlights
Error Code/Symptom 035-XXX-006 (System Board RAID indicates POST error) 075-XXX-001 (Failed Power Supply test) 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Optional Microprocessor test) 165-XXX-001 (Failed System Board test) 175-XXX-001 (Failed Fan 1 test) 175-XXX-002 (Failed Fan 2 test) 175-XXX-003 (Failed Fan 2 test) 175-XXX-004 (Processor Board Temperature sensor out of range) 180-XXX-001 (Failed Information Panel LED test) 180-XXX-002 (Failed Diagnostics LED Panel test) 180-XXX-003 (Failed System Board LED test) 180-XXX-004 (Failed Processor Board LED test) 180-XXX-005 (Failed Hot Swap SCSI Backplane LED test) 201-XXX-001 (Failed Memory test, see"Memory Settings" on page 98 ) 201-XXX-002 (Failed Memory test, see"Memory Settings" on page 98 ) FRU/Action 1. System Board 1. Power Supply 1. Microprocessor 1. Optional Microprocessor 1. System Board 2. Processor Board 3. Power Backplane 4. Hot-Swap Drive Backplane 1. Fan 1 1. Fan 2 1. Fan 3 1. Check system cooling 1. Information LED Panel 1. Diagnostics LED Panel 1. System Board 1. Processor Board 1. Hot Swap SCSI Backplane 1. DIMM Location J1 2. System Board 1. DIMM Location J2 2. System Board 270 Netfinity Server HMM
![](/manual_guide/products/ibm-86605su-maintenance-manual-e887055/275.png)