Intermec IF2 IF2 Network Reader User Manual - Page 55
About BRI Attribute Settings, Tag Types, Read Tries, Write Tries, Lock Tries
View all Intermec IF2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Chapter 3 - Develop and Use RFID Applications About BRI Attribute Settings This section explains the BRI attribute settings that control how the reader operates. For more information, see the Basic Reader Interface Programmer's Reference Manual. Tag Types Check the appropriate check boxes to enable RFID operations for these kinds of tags: • EPC Class 1 Gen 2 (default) • Phillips v1.19 • ISO6B/G1 • ISO6B/G2 This setting is equivalent to the TAGTYPE BRI attribute. Read Tries Sets the maximum number of times the read algorithm is executed before a response is returned to a Read command. In practice, this is the number of times an identified tag is read until the Read is successful. Valid range is 1 to 254 (default is 3). This setting is equivalent to the RDTRIES BRI attribute. Write Tries Sets the maximum number of times the write algorithm is executed before a response is returned to a Write command. In practice, this is the number of times an identified tag is written to until the Write is successful. Valid range is 1 to 254 (default is 3). This setting is equivalent to the WRTRIES BRI attribute. Lock Tries Sets the maximum number of times the lock algorithm is executed before a response is returned to a Lock command. Valid range is 1 to 254 (default is 3). This setting is equivalent to the LOCKTRIES BRI attribute. IF2 Network Reader User Manual 41