Intermec IF2 IF2 Network Reader User Manual - Page 57
Select Tries, Session, Initial Q, Initialization Tries, Develop and Use RFID Applications
View all Intermec IF2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Chapter 3 - Develop and Use RFID Applications 2 Specify the value (in ms) for the antenna or ID timeout in the entry fields and then click Activate Changes. For more information on ID Timeout and Antenna Timeout, see those topics later in this section. Select Tries (Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group select is attempted. A group select is the command that starts the identity process. Valid range is 1 (default) to 254. This setting is equivalent to the SELTRIES BRI attribute. Unselect Tries (Not supported by EPCglobal Class 1 Gen 2 tags) Sets the number of times a group unselect is attempted. Valid range is 1 (default) to 254. Session (EPCglobal Class 1 Gen 2 tags only) Sets the command session parameter to the corresponding EPCglobal Class 1 Gen 2 air protocol command (default is QueryAdjust). This setting is equivalent to the SESSION BRI attribute. For more information on this setting, see the EPCglobal Class 1 Gen 2 documentation. Initial Q (EPCglobal Class 1 Gen 2 tags only) Sets the initial Q parameter value used by the Query command. Valid range is 0 to 15 (default is 4). If you know there is only one tag in the field, set this attribute to 0 for best performance. This setting is equivalent to the INITIALQ BRI attribute. Initialization Tries Sets the maximum number of times the reader attempts to initialize a tag. Valid range is 1 (default) to 254. This setting is equivalent to the INITTRIES BRI attribute. IF2 Network Reader User Manual 43