Lantronix IntelliBox-I/O IntelliBox-I/O - User Guide - Page 147

EventTrak Control, Step A Settings, Description

Page 147 highlights

13: EventTrak Pages The additional settings are described below: Table 13-4 EventTrak Control Step Settings EventTrak Control Step A Settings Advance to Step "B" if Description This setting defines the event that will cause EventTrak to move to the next step. When you use an option, the Upon Advance setting displays. Note: In Step "B", this is entitled Advance to Step "C" if. In Step "C", this is entitled Advance to Step "D". Choices are: Never = there is no event that advances to the next step. Match String "x" = tells EventTrak to monitor the serial port and advance if it detects a specific string. The choices are Match String 1, Match String 2 or Match String 3. (See EventTrak - Monitoring Page for instructions on defining match strings.) Line outputs data = advances if data is sent out the serial port. Tunnel accepts connection = tells EventTrak to advance if the IntelliBox accepts a TCP connection to its serial port. Tunnel accepts disconnection = tells EventTrak to advance if a TCP connection to its serial port is disconnected. Ping Response = tells EventTrak to advance if the IntelliBox receives a ping response. This setting works in conjunction with the initial action of Ping per second. Timeout expires = tells EventTrak to wait a configurable amount of time before advancing. This is useful when you want to pause EventTrak to wait for an event or gather serial data for automated reporting. You can configure the timeout as milliseconds, seconds or minutes. The maximum length of a timeout is 10080 minutes (7 days). Triggered by task "x" = allows EventTrak to advance when another triggers it. Upon Advance Externally triggered = Allows EventTrak to advance when another task on another EventTrak triggers it. This setting tells EventTrak what actions to take when a detected event causes EventTrak to move to the next step. Note: Upon Advance happens at the same time as moving to the next step. The Upon Advance box displays when you select Advance to step "x". Note: You can add multiple actions. Choices are: Send Email = tells EventTrak to send an email when it detects an event. When you select an option, the following additional configurable items display:  No Email removes Send email as an action in response IntelliBox-I/O 2100 User Guide 147

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

13: EventTrak Pages
IntelliBox-I/O 2100 User Guide
147
The additional settings are described below:
Table 13-4 EventTrak Control Step Settings
EventTrak Control
Step A Settings
Description
Advance to Step "B" if
This setting defines the event that will cause EventTrak to move to the
next step. When you use an option, the
Upon Advance
setting displays.
Note:
In Step “B”, this is entitled Advance to Step “C” if. In Step “C”, this
is entitled Advance to Step “D”.
Choices are:
Never
= there is no event that advances to the next step.
Match String “x”
= tells EventTrak to monitor the serial port and
advance if it detects a specific string. The choices are
Match String 1
,
Match String 2
or
Match String 3
. (See EventTrak – Monitoring Page
for instructions on defining match strings.)
Line outputs data
= advances if data is sent out the serial port.
Tunnel accepts connection
= tells EventTrak to advance if the
IntelliBox accepts a TCP connection to its serial port.
Tunnel accepts disconnection
= tells EventTrak to advance if a TCP
connection to its serial port is disconnected.
Ping Response
= tells EventTrak to advance if the IntelliBox receives a
ping response. This setting works in conjunction with the initial action of
Ping per second
.
Timeout expires
= tells EventTrak to wait a configurable amount of time
before advancing. This is useful when you want to pause EventTrak to
wait for an event or gather serial data for automated reporting. You can
configure the timeout as milliseconds, seconds or minutes. The
maximum length of a timeout is 10080 minutes (7 days).
Triggered by task “x”
= allows EventTrak to advance when another
triggers it.
Externally triggered
= Allows EventTrak to advance when another task
on another EventTrak triggers it.
Upon Advance
This setting tells EventTrak what actions to take when a detected
event causes EventTrak to move to the next step.
Note:
Upon Advance happens at the same time as moving to the
next step.
The
Upon Advance
box displays when you select
Advance to step
“x”
.
Note:
You can add multiple actions.
Choices are:
Send Email
= tells EventTrak to send an email when it detects an
event. When you select an option, the following additional
configurable items display:
No Email
removes
Send email
as an action in response