Lantronix IntelliBox-I/O IntelliBox-I/O - User Guide - Page 92
LPD Settings, Description, Table 9-9 LPD Configuration
View all Lantronix IntelliBox-I/O manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
9: Services Settings Table 9-9 LPD Configuration LPD Page Settings Banner Binary Start of Job End of Job Description Select Enabled to print the banner even if the print job does not specify to do so. Selected by default. Select Enabled for the device to pass the entire file to the printer unchanged. Otherwise, the device passes only valid ASCII and valid control characters to the printer. Valid control characters include the tab, linefeed, formfeed, backspace, and newline characters. All others are stripped. Disabled by default. Select Enabled to print a "start of job" string before sending the print data. Select Enabled to send an "end of job" string. Formfeed Convert Newlines SOJ String EOJ String Queue Name Select Enabled to force the printer to advance to the next page at the end of each print job. Select Enabled to convert single newlines and carriage returns to DOS-style line endings. . If Start of Job (above) is enabled, enter the string to be sent to the printer at the beginning of a print job. The limit is 100 characters. Indicate whether the string is in text or binary format. If End of Job (above) is enabled, enter the string to send at the end of a print job. The limit is 100 characters. Indicate whether the string is in text or binary format. To change the name of the print queue, enter a new name. The name cannot have white space in it and is limited to 31 characters. The default is LPDQueueX (for line number X). IntelliBox-I/O 2100 User Guide 92