Lantronix IntelliBox-I/O IntelliBox-I/O - User Guide - Page 25

Other Examples, Security and Theft Prevention

Page 25 highlights

3: EventTrak Detect fluid levels (float sensor connected to the IntelliBox's digital input)  At low level, the IntelliBox triggers its relay to start a fluid pump. If the fluid lever is abnormally low, the IntelliBox sends an email indicating the problem and the action taken.  At high level, IntelliBox triggers its relay to stop a fluid pump or open a valve to release the fluid. If the fluid level is abnormally high, the IntelliBox sends an email indicating the problem and the action taken. Detect pressure (using a digital pressure sensor connected to the IntelliBox digital input)  Shuts off the valve or opens an emergency valve when it detects high pressure.  Turns off a pump or motor.  Notifies the user by email. Monitor a PLC (connected to the IntelliBox's serial port)  Queries the device.  Sends reports by email and RSS Feed (monitor using an RSS client or a web browser).  Scans for specific data. When the IntelliBox detects the data, it can automatically: o Reconfigure the attached device o Soft reboot the attached device (through the serial port) o Hard reboot the attached device (using the relay) o Trigger an alarm (using the relay) Other Examples Security  Controls a camera using proximity sensors (e.g., zoom, pan, and rotate). Security and Theft Prevention  Monitors an attached device.  If the device disconnects, sends an email or triggers an alarm (for example). HVAC Systems  Preemptively notifies the user of equipment failure.  Initiates emergency shutdown or startup.  Automatically reports HVAC status (email with attached data).  Performs consolidated monitoring of many HVAC systems (RSS feed to a web browser). IntelliBox-I/O 2100 User Guide 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

3: EventTrak
IntelliBox-I/O 2100 User Guide
25
Detect fluid levels (float sensor connected to the IntelliBox’s digital input)
At low level, the IntelliBox triggers its relay to start a fluid pump. If the fluid lever is
abnormally low, the IntelliBox sends an email indicating the problem and the action
taken.
At high level, IntelliBox triggers its relay to stop a fluid pump or open a valve to
release the fluid. If the fluid level is abnormally high, the IntelliBox sends an email
indicating the problem and the action taken.
Detect pressure (using a digital pressure sensor connected to the IntelliBox digital
input)
Shuts off the valve or opens an emergency valve when it detects high pressure.
Turns off a pump or motor.
Notifies the user by email.
Monitor a PLC (connected to the IntelliBox’s serial port)
Queries the device.
Sends reports by email and RSS Feed (monitor using an RSS client or a web
browser).
Scans for specific data. When the IntelliBox detects the data, it can automatically:
o
Reconfigure the attached device
o
Soft reboot the attached device (through the serial port)
o
Hard reboot the attached device (using the relay)
o
Trigger an alarm (using the relay)
Other Examples
Security
Controls a camera using proximity sensors (e.g., zoom, pan, and rotate).
Security and Theft Prevention
Monitors an attached device.
If the device disconnects, sends an email or triggers an alarm (for example).
HVAC Systems
Preemptively notifies the user of equipment failure.
Initiates emergency shutdown or startup.
Automatically reports HVAC status (email with attached data).
Performs consolidated monitoring of many HVAC systems (RSS feed to a web
browser).