Lantronix IntelliBox-I/O IntelliBox-I/O - User Guide - Page 66

Enabled, Disabled, Email, Relay, Exclusive Control, Logical-Or, Email on Connect

Page 66 highlights

7: Network, Serial Line, Tunnel, and Modbus Settings Tunnel - Accept Mode Page Settings Block Serial Block Network Password Prompt for Password Email on Connect Email on Disconnect Output Selection Mode RSS Trace Connections Description Select whether incoming serial data should be discarded. This setting is used for debugging purposes. Choices are: On = discard all incoming serial data on the respective interface. Off = do not discard all incoming serial data. (default) Select whether incoming network data should be discarded. This setting is used for debugging purposes. Choices are: On = discard all incoming network data on the respective interface. Off = do not discard all incoming network data. (default) Enter a password that clients must send to the IntelliBox within 30 seconds from opening a network connection to enable data transmission. The password can have up to 31 characters and must contain only alphanumeric characters and punctuation. When set, the password sent to the IntelliBox must be terminated with one of the following: (a) 0x10 (LF), (b) 0x00, (c) 0x13 0x10 (CR LF), or (d) 0x13 0x00. Indicate whether the user should be prompted for the password upon connection. Enabled = prompt for a password upon connection. Disabled = do not prompt for a password upon connection. Select whether an email is sent when a connection is made. None = do not send an email. Email # = send an email corresponding to the tunnel number. Select whether an email corresponding to the tunnel number is sent when a connection is closed. None = do not send an email. Email # = send an email corresponding to the tunnel number. Select the output to be closed while a connection is active. None XI01 = output from digital port 1 XI02 = output from digital port 2 Relay = output from the relay Select whether the same output may also be closed by another condition (e.g. Connect Mode settings from Tunnel 1 and Tunnel 2 for the same digital port.) Exclusive Control = same output may not be closed by another condition. Logical-Or = same output may be closed by another condition. Select to enable or disable RSS Trace Connections. IntelliBox-I/O 2100 User Guide 66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

7: Network, Serial Line, Tunnel, and Modbus Settings
IntelliBox-I/O 2100 User Guide
66
Tunnel –
Accept Mode
Page Settings
Description
Block Serial
Select whether incoming serial data should be discarded. This setting is
used for debugging purposes. Choices are:
On
= discard all incoming serial data on the respective interface.
Off
= do not discard all incoming serial data. (default)
Block Network
Select whether incoming network data should be discarded. This setting
is used for debugging purposes. Choices are:
On
= discard all incoming network data on the respective interface.
Off
= do not discard all incoming network data. (default)
Password
Enter a password that clients must send to the IntelliBox within 30
seconds from opening a network connection to enable data
transmission.
The password can have up to 31 characters and must contain only
alphanumeric characters and punctuation. When set, the password sent
to the IntelliBox must be terminated with one of the following: (a) 0x10
(LF), (b) 0x00, (c) 0x13 0x10 (CR LF), or (d) 0x13 0x00.
Prompt for
Password
Indicate whether the user should be prompted for the password upon
connection.
Enabled
= prompt for a password upon connection.
Disabled
= do not prompt for a password upon connection.
Email on Connect
Select whether an email is sent when a connection is made.
None
= do not send an email.
Email #
= send an email corresponding to the tunnel number.
Email on
Disconnect
Select whether an email corresponding to the tunnel number is sent
when a connection is closed.
None
= do not send an email.
Email #
= send an email corresponding to the tunnel number.
Output
Selection
Select the output to be closed while a connection is active.
None
XI01
=
output from digital port 1
XI02
=
output from digital port 2
Relay
=
output from the relay
Mode
Select whether the same output may also be closed by another
condition (e.g. Connect Mode settings from Tunnel 1 and Tunnel 2 for
the same digital port.)
Exclusive Control
= same output may not be closed by another
condition.
Logical-Or
= same output may be closed by another condition.
RSS Trace
Connections
Select to enable or disable RSS Trace Connections.