Introduction 1.13 Power Requirements The DSTni-XPress DR is normally powered by the same 12Vor 24VDC supply that powers other devices in your panel. Many AC-powered industrial controllers also supply 24VDC for use by field devices. The DSTni-XPress DR is not shipped with a separate power supply, but any power supply between 9-30VDC or 9-24VAC can be used. The unit requires a maximum of 3 Watts. 9-30VDC 9-24VAC GND DC+ 19 20 21 22 DC- GND 1.14 Reset Switch The unit has a reset switch located on the front panel, above the red LED. RESET RESET F R A L RS232 RS485 10/100BASE-T SERIAL DSTni-XPress DR User Guide 1-15
![](/manual_guide/products/lantronix-xpressdr-xpressdr-xpressdriap-user-guide-38d1008/29.png)
Introduction
1.13 Power Requirements
The DSTni-XPress DR is normally powered by the same 12Vor 24VDC supply that powers
other devices in your panel. Many AC-powered industrial controllers also supply 24VDC for
use by field devices. The DSTni-XPress DR is not shipped with a separate power supply, but
any power supply between 9-30VDC or 9-24VAC can be used. The unit requires a maximum
of 3 Watts.
19
20
21
22
GND
GND
9-30VDC
DC+
DC-
9-24VAC
1.14 Reset Switch
The unit has a reset switch located on the front panel, above the red LED.