Troubleshooting Problem/Message The device server appears to be set up correctly, but you are not communicating with your device attached to the device server across the network. Reason Solution If you are sure that the serial port You can check to see whether setting is correct, then you may there is a socket connection to or not be connecting to the correct from the device server by looking socket of the device server. at the Ready LED. Check the cables and wiring. If the Ready LED is blinking consistently then there is a good socket connection. When connecting to the WebManager within the device server, the message "No Connection With CoBox" displays. Your computer is not able to connect to port 30718 (77FEh) on the device server. If the Ready LED is solid green, then the socket connection does not exist. Use the Connect Mode option C0 for making a connection to the device server from the network. Use Connect Mode option C1 or C5 for a connection to the network from the device server. See the full list of Connect Mode Options in the Binary to Hexadecimal chapter. Make sure that port 30718 (77FEh) is not blocked with any router that you are using on the network. Also make sure that port 77FEh is not disabled within the Security settings of the device server. DSTni-XPress DR User Guide 6-5