Maytag MED5800TW Technical Education - Page 11
Mobile Home - Additional Installation Re, quirements, Mobile home installations require
View all Maytag MED5800TW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
18" * (45.7 cm) 14" max.* (35.6cm) 48 in. 2 * (310 cm2) 3"* (7.6 cm) 24 in.2* (155 cm2) 1 " 29" 1" 1"* 27¾" 5"* (2.5 cm) (73.66 cm) (2.5 cm) (2.5 cm) (70.5 cm) (12.7 cm) A B C A. Recessed area B. Side view - closet or confined area C. Closet door with vents *Required spacing 3"* (7.6 cm) Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280), or the Canadian Manufactured Home Standard CAN/CSA-Z240 MH. Mobile home installations require: • Metal exhaust system hardware, which is available for purchase from your dealer. • Mobile home Installation Kit Part Number 346764. • Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening. 2-3