Maytag MED5800TW Technical Education - Page 68
Activating The Test Mode, Test Mode Functionality
View all Maytag MED5800TW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Activating The Test Mode 1. Set the following configuration: • Door - must be open • Temperature switch - Air Fluff • End of Cycle Signal switch - Louder • Timer - Timed Drying or Sensor Drying selection 2. Turn the Wrinkle Prevent switch from Off to On three times within a five second period. A single beep, a pause, then a single beep will sound to indicate that the test mode is activated. NOTE: If any of these initial conditions are not satisfied, the control will not enter the test mode. Test Mode Functionality When the control is in test mode, every input change of state will result in an audible beep (with the exception of the End of Cycle Signal switch). This includes: • Door switch • Moisture Sensor (short/open Sensor will result in a beep) NOTE: A moistened finger or damp cloth may also be used. • Temperature switch • Wrinkle Prevent switch • Push to Start (PTS) switch (with the door switch closed) • Timer (any cam input change will result in a beep) NOTE: Timer will advance during test. If any of the inputs do not result in a beep, proceed to the corresponding component tests. 6-2