Maytag MED5800TW Technical Education - Page 19

wire connection: Power Supply Cord, Use where local codes permit connecting, cabinet-ground

Page 19 highlights

3. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw. A B C F E D A. External ground conductor screw B. Center silver-colored terminal block screw C. Neutral wire (white or center wire) D. 3/4" (1.9 cm) UL listed strain relief E. Ground wire (green or bare) of power supply cable F. Neutral ground wire 4. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. 3-wire connection: Power Supply Cord Use where local codes permit connecting cabinet-ground conductor to neutral wire. B D E A C GF A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with upturned ends E. 3/4" (1.9 cm) UL listed strain relief F. Ring terminals G. Neutral (white or center wire) 1. Loosen or remove center silver-colored terminal block screw. 2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw. B C D 5. Tighten strain relief screw. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 7. You have completed your electrical connection. Now go to "Venting Requirements," page 2-17. E A A. Neutral ground wire B. External ground conductor screw C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. 3/4" (1.9 cm) UL listed strain relief 3. Connect the other wires to outer terminal block screws. Tighten screws. 2-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

2-11
3.
Connect ground wire (green or bare) of
power supply cable to external ground
conductor screw. Tighten screw.
5.
Tighten strain relief screw.
6.
Insert tab of terminal block cover into slot
of dryer rear panel. Secure cover with
hold-down screw.
7.
You have completed your electrical con-
nection. Now go to “Venting Require-
ments,” page 2-17.
External ground conductor screw
.
A
Center silver-colored terminal block screw
.
B
Neutral wire (white or center wire)
.
C
.
D
Ground wire (green or bare) of power supply cable
3/4
(1.9 cm) UL listed strain relief
.
E
Neutral ground wire
.
F
"
E
D
A
B
C
F
4.
Place the hooked ends of the other pow-
er supply cable wires under the outer ter-
minal block screws (hooks facing right).
Squeeze hooked ends together. Tighten
screws.
3-wire connection: Power Supply Cord
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with upturned ends
E.
" (1.9 cm) UL listed strain relief
3/4
F. Ring terminals
G. Neutral (white or center wire)
A
B
D
C
E
F
G
1.
Loosen or remove center silver-colored
terminal block screw.
2.
Connect neutral wire (white or center
wire) of power supply cord to the center,
silver-colored terminal screw of the ter-
minal block. Tighten screw.
.
A
.
B
Center silver-colored terminal block screw
.
C
External ground conductor screw
Neutral wire (white or center wire)
.
D
.
E
Neutral ground wire
3/4
(1.9 cm) UL listed strain relief
"
A
B
C
D
E
3.
Connect the other wires to outer terminal
block screws. Tighten screws.