Gas Supply Requirements
View all Maytag MED5800TW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
GAS SUPPLY REQUIREMENTS WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 13˝ (33 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. GAS TYPE Natural Gas: This dryer is equipped for use with Natural gas. It is design-certified by CSA International for LP (propane or butane) gases with appropriate conversion. • The dryer must have the correct burner for the type of gas in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer. LP gas conversion: Conversion must be made by a qualified technician. No attempt shall be made to convert the appliance from the gas specified on the model/ serial rating plate for use with a different gas without consulting your gas company. GAS SUPPLY LINE • 1/2˝ IPS pipe is recommended. • 3/8˝ approved aluminum or copper tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. • Must include 1/8˝ NPT minimum plugged tapping accessible for test gauge connection, immediately upstream of the gas connection to the dryer (see illustration below). • If you are using Natural gas, do not use copper tubing. • Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting. • If your dryer has been converted to use LP gas, 3/8˝ LP compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON®† tape. • Must include a shutoff valve: In the U.S.A.: An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. In Canada: An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer. The location should be easy to reach for opening and closing. A C E B D A. ³⁄8" flexible gas connector B. ³⁄8 " pipe to flare adapter fitting C. ¹⁄8 " NPT minimum plugged tapping D. ½" NPT gas supply line E. Gas shutoff valve 2-15