Maytag MED5800TW Technical Education - Page 60

Removing The Drum Light Assembly

Page 60 highlights

REMOVING THE DRUM LIGHT ASSEMBLY WARNING Drum Light Holder Screw Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unplug dryer or disconnect power. 2. Turn off gas supply to dryer. 3. Open the dryer door. 4. Remove the screw from the drum light lens and remove the lens. Drum Bulb 7. Disconnect the wire connectors from the light socket terminals. Socket Wires Socket Drum Light Lens Screw 8. Squeeze the locking arms and remove the socket from the drum light holder. 5. Remove the bulb from the drum light socket (see the top right photo). 6. Remove the screw from the drum light holder and pull it forward so you can access the wires. Socket Locking Arms 4-20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

4-20
REMOVING THE DRUM LIGHT ASSEMBLY
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Open the dryer door.
4.
Remove the screw from the drum light
lens and remove the lens.
Drum Light Lens Screw
5.
Remove the bulb from the drum light
socket (see the top right photo).
6.
Remove the screw from the drum light
holder and pull it forward so you can ac-
cess the wires.
Drum Light
Holder Screw
Drum Bulb
7.
Disconnect the wire connectors from the
light socket terminals.
Socket Wires
8.
Squeeze the locking arms and remove
the socket from the drum light holder.
Socket
Socket Locking Arms
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.