Maytag MED5800TW Technical Education - Page 54
Removing The Thermal Cutoff Tco, Heater, And, Inlet Thermistor / High-limit Thermostat, Electric
View all Maytag MED5800TW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
REMOVING THE THERMAL CUTOFF (TCO), HEATER, AND INLET THERMISTOR / HIGH-LIMIT THERMOSTAT (ELECTRIC MODELS ONLY) WARNING Thermal Cutoff (TCO) Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unplug dryer or disconnect power. 2. Remove the rear panel (see page 4-13 for the procedure). 3. To remove the thermal cutoff (TCO) (see the top round inset): a) Remove the two wires from the TCO terminals. b) Remove the hex-head screw, unhook the end of the bracket, and remove the TCO. 4. To remove the heater and inlet thermistor/high-limit thermostat (see the bottom round inset): a) Lift the locking tab and remove the 2-wire connector from the inlet thermistor. b) Remove the wire connector from the high-limit thermostat terminal. c) Remove the two wire connectors from the heater terminal block. High-Limit Thermostat Connector Screw Inlet Thermistor 2-Wire Connector Heater Terminal Block Connectors 4-14