Motorola 49901 Instruction Manual - Page 67

Setting the Interface Type, Introduction, Interface Type, Parameter, Con gt; Port

Page 67 highlights

Configuring the Serial Interface Setting the Interface Type Introduction This section provides instructions for setting the Interface Type parameter. Interface Type Parameter Use this procedure to set the Interface Type parameter: Step 1 2 3 4 5 Action From the Control Terminal Port Main menu, select Configure -> Port. In the Port Number parameter, type 3, then press ENTER. In the Port Type parameter, type FRI, then press ENTER In the Interfaced Type, type a ?, and then press ENTER. Select an Interface Type from the menu and press ENTER. Result/Description The Port record appears. Port 3 is selected. This defines Port 3 type as FRI. The Range and Default appear: Range = V.24, V.35, V.36, X.21, NONE Default = V.24 Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - V.11 Electrical Interface Type NONE - Electrically disabled The Interface Type is set. Installation and Replacement 3-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121

Installation and Replacement
3-9
Configuring the Serial Interface
Setting the Interface Type
Introduction
This section provides instructions for setting the Interface Type parameter.
Interface Type
Parameter
Use this procedure to set the Interface Type parameter:
Step
Action
Result/Description
1
From the Control Terminal
Port Main menu, select
Configure -> Port
.
The Port record appears.
2
In the Port Number parameter,
type
3
, then press ENTER.
Port 3 is selected.
3
In the Port Type parameter,
type
FRI
, then press ENTER
This defines Port 3 type as FRI.
4
In the Interfaced Type, type a
?
, and then press ENTER.
The Range and Default appear:
Range = V.24, V.35, V.36, X.21, NONE
Default = V.24
Specify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - V.11 Electrical Interface Type
NONE - Electrically disabled
5
Select an Interface Type from
the menu and press ENTER.
The Interface Type is set.