Panasonic AJSPX800P AJSPX800 User Guide - Page 107

<Note&gt

Page 107 highlights

Items/ Adjustable Data Saved Range Remarks Items/ Adjustable Data Saved Range Remarks DIONIC90 _ • AUTO MANUAL 11.0 : 13.6 : - C U F - 15.0 Enable selection under BATTERY SELECT. _: Enable selection. • : Disable selection. Select auto or manual to set the NEAR END voltage. AUTO: Set voltage automatically. MANUAL: Set voltage manually. When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. ENDURA50 _ • AUTO MANUAL 11.0 : 13.1 : - C U F - 15.0 Enable selection under BATTERY SELECT. _: Enable selection. • : Disable selection. Select auto or manual to set the NEAR END voltage. AUTO: Set voltage automatically. MANUAL: Set voltage manually. When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. DIONIC160 _ Enable selection under BATTERY SELECT. ENDURA80 _ Enable selection under BATTERY SELECT. • _: Enable selection. • : Disable selection. • _: Enable selection. • : Disable selection. AUTO Select auto or manual to set the NEAR END AUTO Select auto or manual to set the NEAR END MANUAL voltage. MANUAL voltage. AUTO: Set voltage automatically. AUTO: Set voltage automatically. MANUAL: Set voltage manually. MANUAL: Set voltage manually. 11.0 When MANUAL is selected in the menu 11.0 When MANUAL is selected in the menu : 13.3 : - C U F - 15.0 above, set the NEAR END voltage in 0.1 V steps. : 13.1 : - C U F - 15.0 above, set the NEAR END voltage in 0.1 V steps. 8 HP-90L _ Enable selection under BATTERY SELECT. BP-L60/90 _ Enable selection under BATTERY SELECT. • _: Enable selection. • : Disable selection. • _: Enable selection. • : Disable selection. AUTO Select auto or manual to set the NEAR END AUTO Select auto or manual to set the NEAR END MANUAL voltage. MANUAL voltage. AUTO: Set voltage automatically. AUTO: Set voltage automatically. MANUAL: Set voltage manually. MANUAL: Set voltage manually. 11.0 When MANUAL is selected in the menu 11.0 When MANUAL is selected in the menu : 12.4 : - C U F - 15.0 above, set the NEAR END voltage in 0.1 V steps. : 11.2 : - C U F - 15.0 above, set the NEAR END voltage in 0.1 V steps. BP-H120 _ • AUTO MANUAL 11.0 : 11.5 : - C U F - 15.0 NP-L50 _ • AUTO MANUAL 11.0 : 13.0 : - C U F - 15.0 Enable selection under BATTERY SELECT. _: Enable selection. • : Disable selection. Select auto or manual to set the NEAR END voltage. AUTO: Set voltage automatically. MANUAL: Set voltage manually. When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. Enable selection under BATTERY SELECT. _: Enable selection. • : Disable selection. Select auto or manual to set the NEAR END voltage. AUTO: Set voltage automatically. MANUAL: Set voltage manually. When MANUAL is selected in the menu above, set the NEAR END voltage in 0.1 V steps. The remaining battery capacity for digital batteries is displayed as % inside the viewfinder (PRO14/TRIM14/HYTRON50/ HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50). The BATT NEAR END alarm, however, is triggered according to the setting on the screen, regardless of the % indication. The ____ in the Adjustable Range column indicates the preset mode. 107

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

107
8
<Note>
The remaining battery capacity for digital batteries is displayed
as % inside the viewfinder (PRO14/TRIM14/HYTRON50/
HYTRON100/HYTRON120/DIONIC90/DIONIC160/NP-L50).
The BATT NEAR END alarm, however, is triggered according to
the setting on the <BATTERY SETTING1> screen, regardless of
the % indication.
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved
Adjustable
Range
Remarks
DIONIC90
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
1
3.6
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
DIONIC160
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
1
3.3
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
HP-90L
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
12.4
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
BP-H120
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
1
1.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
NP-L50
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
1
3.0
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
Items/
Data Saved
Adjustable
Range
Remarks
ENDURA50
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
1
3.1
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
ENDURA80
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
13.1
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–
BP-L60/90
Enable selection under BATTERY SELECT.
:
Enable selection.
• :
Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR END
voltage.
AUTO:
Set voltage automatically.
MANUAL
:
Set voltage manually.
11.0
:
11.2
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.
–CUF–