Panasonic AJSPX800P AJSPX800 User Guide - Page 110

Tc/ub, Umid Set/info

Page 110 highlights

8-6-6 TC/UB Items/ Adjustable Data Saved Range Remarks TC MODE DF NDF -CUF - Set the time code mode. DF: Drop frame. NDF: Non drop frame. UB MODE USER TIME DATE EXT TCG FRM RATE REGEN -CUF - Select the user bits mode. USER:Select UB value set in the LCD section. TIME: Select local time (hours, minutes, seconds). DATE: Select local date and time (2 last digits of year, month, date, time). EXT: Slaved to UB from TC-IN. If reading fails, USER value is retained. TCG: TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in the card and record value continuously. VITC UB MODE USER/EXT TIME DATE TCG FRM RATE REGEN -CUF - Select the user bits mode for VAUX TC (VITC). USER/EXT: If UB MODE is set to EXT, the EXT value is recorded. If not, USER value set by UB is recorded. TIME: Select local time (hours, minutes, seconds). DATE: Select local date and time (2 last digits of year, month, date, time). TCG: TCG value enters UB. FRM RATE: Select same camera shoting information (frame rate, etc.) with the VAUX UB (VITC UB). REGEN:Read out value stored in card and record value continuously. TCG SET HOLD ON OFF -CUF - ON/OFF switching for the feature that always starts recording (when the power is turned ON again) the TCG value that was set before the power is turned OFF. FIRST REC TC REGEN PRESET -CUF - For the first recording after the power is turned on, a P2 card is inserted and then switching from this P2 card to another recording-target P2 card is performed, select whether or not to regenerate the time code as the value on the new P2 card. REGEN:For clips recorded on the recording- target P2 card, regenerate the time code as the time code of the clip that has the most recent date and time. PRESET: Use the camera-recorder's internal time code. Set the date and time accurately. For guidance on setting, see [4-5-2 Setting the Internal Clock's Date and Time]. P.OFF LCD ON DISPLAY OFF -CUF - Select whether or not to display the time code setting and counter indication on the LCD monitor when the power is turned OFF. ON: Display setting and indication while the power is turned OFF. OFF: Power-down LCD monitor while camera power is turned OFF. Setting and indication disabled. Items/ Adjustable Data Saved Range Remarks TC OUT TCG TCG/TCR -CUF - Select the time code to be output to the time code output connector. TCG: Always output time code generator value. TCG/TCR: Display time code generator value in E-E mode, and time code reader value in V-V mode. TC DISP SEL 30F 24F -CUF - Select the display format for the time code frame digits. 30F: Display time code frame digits in 30 frames. 24F: Convert time code frame digits into 24 frames for display. 8-6-7 UMID SET/INFO Items/ Adjustable Data Saved Range Remarks COUNTRY NO-INFO Input the user's country. NO-INFO is displayed until the input completes. -CUF - ORGANIZATION NO-INFO -CUF - Input the user's organisation or company name. NO-INFO is displayed until the input completes. USER NO-INFO Input the user name. NO-INFO is displayed until the input completes. -CUF - DEVICE NODE Indicate the product ID number. ----- Please refer to [4-5-6 Setting the UMID Information] for the UMID information setting. The ____ in the Adjustable Range column indicates the preset mode. 110

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116

110
8-6-6
TC/UB
8-6-7
UMID SET/INFO
<Note>
Please refer to [4-5-6 Setting the UMID Information] for the
UMID information setting.
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved
Adjustable
Range
Remarks
TC MODE
DF
NDF
Set the time code mode.
DF:
Drop frame.
NDF:
Non drop frame.
–CUF–
UB MODE
USER
TIME
DATE
EXT
TCG
FRM RATE
REGEN
Select the user bits mode.
USER:
Select UB value set in the LCD
section.
TIME:
Select local time (hours, minutes,
seconds).
DATE:
Select local date and time (2 last
digits of year, month, date, time).
EXT:
Slaved to UB from TC-IN. If reading
fails, USER value is retained.
TCG:
TCG value enters UB.
FRM RATE:
Select same camera shoting
information (frame rate, etc.) with the
VAUX UB (VITC UB).
REGEN
:
Read out value stored in the card
and record value continuously.
–CUF–
VITC UB MODE
USER/EXT
TIME
DATE
TCG
FRM RATE
REGEN
Select the user bits mode for VAUX TC
(VITC).
USER/EXT:
If UB MODE is set to EXT, the EXT
value is recorded. If not, USER value
set by UB is recorded.
TIME:
Select local time (hours, minutes,
seconds).
DATE:
Select local date and time (2 last
digits of year, month, date, time).
TCG:
TCG value enters UB.
FRM RATE:
Select same camera shoting
information (frame rate, etc.) with the
VAUX UB (VITC UB).
REGEN
:
Read out value stored in card and
record value continuously.
–CUF–
TCG SET HOLD ON
OFF
ON/OFF switching for the feature that
always starts recording (when the power is
turned ON again) the TCG value that was
set before the power is turned OFF.
–CUF–
FIRST REC TC
REGEN
PRESET
For the first recording after the power is
turned on, a P2 card is inserted and then
switching from this P2 card to another
recording-target P2 card is performed,
select whether or not to regenerate the time
code as the value on the new P2 card.
REGEN:
For clips recorded on the recording-
target P2 card, regenerate the time
code as the time code of the clip that
has the most recent date and time.
PRESET:
Use the camera-recorder’s internal
time code.
<Note>
Set the date and time accurately. For
guidance on setting, see [4-5-2 Setting the
Internal Clock’s Date and Time].
–CUF–
P.OFF LCD
DISPLAY
ON
OFF
Select whether or not to display the time
code setting and counter indication on the
LCD monitor when the power is turned OFF.
ON:
Display setting and indication while
the power is turned OFF.
OFF:
Power-down LCD monitor while
camera power is turned OFF. Setting
and indication disabled.
–CUF–
Items/
Data Saved
Adjustable
Range
Remarks
TC OUT
TCG
TCG/TCR
Select the time code to be output to the time
code output connector.
TCG:
Always output time code generator
value.
TCG/TCR:
Display time code generator value in
E-E mode, and time code reader
value in V-V mode.
–CUF–
TC DISP SEL
30F
24F
Select the display format for the time code
frame digits.
30F:
Display time code frame digits in 30
frames.
24F:
Convert time code frame digits into
24 frames for display.
–CUF–
Items/
Data Saved
Adjustable
Range
Remarks
COUNTRY
NO-INFO
Input the user’s country. NO-INFO is
displayed until the input completes.
–CUF–
ORGANIZATION
NO-INFO
Input the user’s organisation or company
name. NO-INFO is displayed until the input
completes.
–CUF–
USER
NO-INFO
Input the user name. NO-INFO is displayed
until the input completes.
–CUF–
DEVICE NODE
Indicate the product ID number.
–––––