4. Self-diagnosis Code Table Self-diagnosis Code Repaired by: Block Detailed Function Code Symptom/State Correction C 2 1 0 0 Condensation. Remove the cassette, and insert it again after one hour. C 2 2 0 0 Video head is dirty. Clean with the optional cleaning cassette. C 2 3 0 0 Non-standard battery is used. Use the InfoLITHIUM battery. LOAD direction. Loading does not C 3 1 1 0 complete within specified time Load the tape again, and perform operations from the beginning. C3 11 UNLOAD direction. Loading does not 1 complete within specified time Load the tape again, and perform operations from the beginning. C 3 1 2 0 T reel side tape slacking when unloading. Load the tape again, and perform operations from the beginning. C 3 1 2 1 S reel side tape slacking when unloading. Load the tape again, and perform operations from the beginning. C 3 1 2 2 T reel fault Load the tape again, and perform operations from the beginning. C 3 1 2 3 S reel fault Load the tape again, and perform operations from the beginning. C 3 1 3 0 FG fault when starting capstan Load the tape again, and perform operations from the beginning. C 3 1 3 1 FG fault during normal capstan operations Load the tape again, and perform operations from the beginning. C 3 1 4 0 FG fault when starting drum Load the tape again, and perform operations from the beginning. C 3 1 4 1 PG fault when starting drum Load the tape again, and perform operations from the beginning. C 3 1 4 2 FG fault during normal drum operations Load the tape again, and perform operations from the beginning. C 3 1 4 3 PG fault during normal drum operations Load the tape again, and perform operations from the beginning. C 3 1 4 4 Phase fault during normal drum operations Load the tape again, and perform operations from the beginning. C3 21 0 LOAD direction loading motor time-out Remove the battery or power cable, connect, and perform operations from the beginning. UNLOAD direction loading motor time- Remove the battery or power cable, connect, and perform operations C 3 2 1 1 out from the beginning. C3 22 0 T reel side tape slacking when unloading. Remove the battery or power cable, connect, and perform operations from the beginning. C3 22 1 S reel side tape slacking when unloading. Remove the battery or power cable, connect, and perform operations from the beginning. C 3 2 2 2 T reel fault Remove the battery or power cable, connect, and perform operations from the beginning. C 3 2 2 3 S reel fault Remove the battery or power cable, connect, and perform operations from the beginning. C 3 2 3 0 FG fault when starting capstan Remove the battery or power cable, connect, and perform operations from the beginning. C3 23 1 FG fault during normal capstan operations Remove the battery or power cable, connect, and perform operations from the beginning. C 3 2 4 0 FG fault when starting drum Remove the battery or power cable, connect, and perform operations from the beginning. C 3 2 4 1 PG fault when starting drum Remove the battery or power cable, connect, and perform operations from the beginning. C3 24 2 FG fault during normal drum operations Remove the battery or power cable, connect, and perform operations from the beginning. C3 24 3 PG fault during normal drum operations Remove the battery or power cable, connect, and perform operations from the beginning. C3 24 4 Phase fault during normal drum operations Remove the battery or power cable, connect, and perform operations from the beginning. Inspect the lens block focus reset sensor (Pin !ª of CN551 of VC-215 board) when focusing is performed when the focus dial is rotated in the Difficult to adjust focus E 6 1 0 0 (Cannot initialize focus.) focus manual mode and the focus motor drive circuit (IC552 of VC-215 board) when the focusing is not performed. Note : Use the remote commander RM-95 only for the model without the focus dial. Inspect the lens block zoom reset sensor (Pin @¡ of CN551 of VC-215 Zoom operations fault E 6 1 1 0 (Cannot initialize zoom lens.) board) when zooming is performed when the zoom lens is operated and the zoom motor drive circuit (IC552 of VC215 board) when zooming is not performed. E6 20 Handshake correction function does not 0 work well.(With pitch angular velocity sensor output stopped) Inspect yaw angular velocity sensor (SE451 of SE-80/81 board) peripheral circuits. E6 20 Handshake correction function does not 1 work well.(With yaw angular velocity sensor output stopped) Inspect pitch angular velocity sensor (SE452 of SE-80/81 board) peripheral circuits.