Camera System Adjustments
UPC - 027242551497
View all Sony CCD TRV16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
1-3. CAMERA SYSTEM ADJUSTMENTS Before perform the camera system adjustments, Check that the specified value of "28MHz Origin Oscillation Adjustment", "Y OUT level Adjustment" and "C OUT level Adjustment" of "VIDEO SYSTEM ADJUSTMENT" are satisfied. 1. G-CAM flip Adjustment Set the color reproduction conditions to optimum. Subject Measurement Point Measuring Instrument Color bar chart standard picture frame Display data of page 1 of the adjusting remote commander (Note 1) Adjustment Page F Adjustment Address 21 Note 1. Displayed data of page 1 of the adjusting remote commander. 1 : XX : XX n S2 n S1 Note 2. [ ] : CCD-TR516/TR516PK CCD-TRV36/TRV36PK < > : CCD-TR716 CCD-TRV43/TRV46/TRV46PK Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 0, address: 03, and set data: 16. 3) Select page 1 of the adjusting remote commander, and compare the higher 2 digits (S1) and lower 2 digits (S2) of the 4-degits display data. When S1